The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determination of total lipid using non-chlorinated solvents
Abstract
The restrictions on the use of chlorinated solvents under the Montreal Protocol makes it necessary to develop an alternative method to the Bligh and Dyer lipid extraction as currently applied to marine tissues. Several different solvent mixtures were systematically tested as a replacement for chloroform. The presence of a polar solvent is a prerequisite in order to obtain phase separation between the aqueous and organic phases, but too high a concentration of solvent in the aqueous phase prevents the more polar lipids from being extracted. A high content of water in the organic phase can result in co-extraction of non-lipids. Several combinations of solvents may be able to extract lipids, but for reasons of safety and toxicity, a propan-2-ol–cyclohexane–water (8 + 10 + 11 v/v/v) mixture has been proposed. The method is not sensitive to a wide range of sample-phase volume ratios provided that the solvent compositions remain constant. Application to plaice, mussel and herring samples showed results that were in agreement with the extraction following Bligh and Dyer using chloroform and methanol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of selected lipid methods for normalizing pollutant bioaccumulation
Randall, R. C., Lee, H., Ozretich, R. J., Lake, J. L., & Pruell, R. J. (1991) · Environmental Toxicology and Chemistry · doi:10.1002/etc.5620101108 · Cited by 98
Cited by
On the Use of Stable Isotopes in Trophic Ecology
Boecklen, W. J., Yarnes, C. T., Cook, B. A., & James, A. C. (2011) · Annual Review of Ecology, Evolution, and Systematics · doi:10.1146/annurev-ecolsys-102209-144726 · Cited by 1,065
Advances in Lipid Extraction Methods—A Review
Saini, R. K., Prasad, P., Shang, X., & Keum, Y.-S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413643 · Cited by 479
Covaci, A. (2003) · Environment International · doi:10.1016/s0160-4120(03)00114-4 · Cited by 425
Biodiesel production from biomass of an oleaginous fungus
Vicente, G., Bautista, L. F., Rodríguez, R., Gutiérrez, F. J., Sádaba, I., Ruiz-Vázquez, R. M., Torres-Martínez, S., & Garre, V. (2009) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.07.014 · Cited by 300
Deutsch, K., Leroy, D., Belpaire, C., den Haan, K. H., Vrana, B., Clayton, H., Hanke, G., Ricci, M., Held, A., Gawlik, B. M., et al. (2014) · DIGITAL.CSIC (Spanish National Research Council (CSIC)) · doi:10.2779/833200 · Cited by 269
Metadata
- Authors
- Smedes, F.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1999
- Volume
- 124
- Issue
- 11
- Pages
- 1711-1718
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2074785528
- Cited by
- 355
- References
- 1
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of total lipid using non-chlorinated solvents. https://app.cochat.ai/papers/10.1039/a905904k
- The paper
- Smedes, F. (1999). Determination of total lipid using non-chlorinated solvents. The Analyst. https://doi.org/10.1039/a905904k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.