Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record.

Selenium speciation in enriched and natural samples by HPLC-ICP-MS and HPLC-ESI-MS with perfluorinated carboxylic acid ion-pairing agents

Kotrebai, Mihály, Tyson, Julian F., Uden, Peter C., Birringer, Marc, Block, Eric·2000·The Analyst

Abstract

Selenium-enriched plants, such as hyperaccumulative phytoremediation plants (Astragalus praleongus, 517 micrograms g-1 Se, and Brassica juncea, 138 micrograms g-1 Se in dry sample), yeast (1200, 1922 and 2100, micrograms g-1 Se in dry sample), ramp (Allium tricoccum, 48, 77, 230, 252, 405 and 524 micrograms g-1 Se in dry sample), onion (Allium cepa, 96 and 140 micrograms g-1 Se in dry sample) and garlic (Allium sativum, 68, 112, 135, 296, 1355 micrograms g-1 Se in dry sample) were analyzed by HPLC-ICP-MS for their selenium content and speciation after hot water and enzymatic extractions. Reference samples with natural selenium levels, such as onion and garlic controls, cooking garlic powder, baking yeast powder and a commercial garlic supplement were also analyzed. Selected samples were also examined by HPLC-electrospray ionization (ESI)-MS. HPLC was mostly carried out with 0.1% heptafluorobutanoic acid (HFBA) as ion-pairing agent in 1 + 99 v/v methanol-water solution, but 0.1% trifluoroacetic acid (TFA) in 1 + 99 v/v methanol-water solution was also utilized to permit chromatography for compounds that did not elute with HFBA. More than 75% of the total eluting selenium compounds, based upon element specific detection, were identified from retention time data and standard spiking experiments, and between 60 and 85% of compounds were identified by MS, with up to 25% of the total eluting molecular selenium species being unidentified as yet. Limits of quantification (LOQ, defined as the concentration giving an S/N of 10) for HPLC-ICP-MS were in the range 2-50 ng mL-1 Se in the injected extracts for the selenium-enriched samples and 2-10 ng mL-1 Se for the natural selenium level samples. LOQ values for HPLC-ESI-MS were ca. 100 times higher than those measured by HPLC-ICP-MS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/a906320j

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 243

Metadata

Authors
Kotrebai, M., Tyson, J. F., Uden, P. C., Birringer, M., & Block, E.
Venue
The Analyst
Published
2000
Volume
125
Issue
1
Pages
71-78
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2123252811
Cited by
243
References
0
FWCI
13.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selenium speciation in enriched and natural samples by HPLC-ICP-MS and HPLC-ESI-MS with perfluorinated carboxylic acid ion-pairing agents. https://app.cochat.ai/papers/10.1039/a906320j
The paper
Kotrebai, M., Tyson, J. F., Uden, P. C., Birringer, M., & Block, E. (2000). Selenium speciation in enriched and natural samples by HPLC-ICP-MS and HPLC-ESI-MS with perfluorinated carboxylic acid ion-pairing agents. The Analyst. https://doi.org/10.1039/a906320j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.