CoChat

A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometry

Delves, H. T. · 1970 · The Analyst
Cited by 301

The DOI matches its Crossref record.

Abstract

The concentrations of lead in 10-µl samples of whole blood are accurately determined in less than 5 minutes by atomic-absorption spectrophotometry. After partial oxidation with hydrogen peroxide in micro crucibles made from nickel foil, the samples are volatilised, by using an air-acetylene flame, into a nickel absorption tube situated in the flame.The sensitivity of the method is 1 × 10–10 g of lead per 1 per cent. absorption at 283·3 nm, and the standard deviation is ±4 per cent. at the 3-ng level.Thirty-nine blood samples with lead concentrations ranging from 19 to 245 µg per 100 ml were analysed by the method described and by automated colorimetry involving the use of dithizone. The correlation coefficient between the results of both methods was 0·989.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/an9709500431

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 301

Metadata

Authors
Delves, H. T.
Venue
The Analyst
Published
1970
Volume
95
Issue
1130
Pages
431
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2111333686
Cited by
301
References
0
FWCI
31.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometry. https://app.cochat.ai/papers/10.1039/an9709500431
The paper
Delves, H. T. (1970). A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometry. The Analyst. https://doi.org/10.1039/an9709500431

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.