The DOI matches its Crossref record.
Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier
Abstract
Accuracy in the determination of blood lead is of primary importance in such diverse activities as screening for childhood lead poisoning, occupational exposure monitoring and population surveys. To meet the stringent requirements of the third National Health and Nutrition Examination Survey (NHANES III), a large normative population study to be held from 1988–1994, we needed a method for the determination of lead in blood that was simple, accurate, rugged and of defined accuracy for both calibration and control materials. The recent availability of the National Bureau of Standards Standard Reference Materials 2121–2 and 955, a lead standard solution (10 000 mg l–1) and a certified lead in blood reference material has made it possible to evaluate a method against definitive values and NBS reference materials.In the proposed method, sample preparation consists of a simple dilution (1 + 9) with a matrix modifier which contains 0.5%V/V Triton X-100, 0.2%V/V 16 M nitric acid and 0.2%m/V dibasic ammonium phosphate. This matrix modifier stabilises lead so that the majority of the blood matrix may be removed during the char step. Maximum accuracy in dilution is achieved with the use of autopipettes which have been shown to deliver viscous materials such as blood and serum with high accuracy. The method described in this study has a detection limit of about 0.07 µmol l–1(3 SD) and a precision and accuracy of ±2–5% at the 0.24–2.4 µmol l–1 concentration level. Linearity has been demonstrated up to about 4 µmol l–1. Comparability has been established with the previous blood lead analytical method used in other surveys via the analysis of 435 specimens by both the previous (modified Delves cup) and proposed methods. The equation of the resulting line is [ETA-AAS]= 1.0007[Delves]– 0.051, r= 0.924.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lanphear, B. P. (2000) · Public Health Reports · doi:10.1093/phr/115.6.521 · Cited by 879
Exposures to environmental toxicants and attention deficit hyperactivity disorder in U.S. children
Braun, J. M., Kahn, R. S., Froehlich, T., Auinger, P., & Lanphear, B. P. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9478 · Cited by 573
Exposure of the U.S. population to lead, 1991-1994.
Pirkle, J. L., Kaufmann, R. B., Brody, D. J., Hickman, T., Gunter, E. W., & Paschal, D. C. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.98106745 · Cited by 397
Self-citationRogan, W. J., Dietrich, K. N., Ware, J. H., Dockery, D. W., Salganik, M., Radcliffe, J., Jones, R. L., Ragan, N. B., Chisolm, J. J., & Rhoads, G. G. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105103441902 · Cited by 361
Arsenic Exposure and Cognitive Performance in Mexican Schoolchildren
Rosado, J. L., Ronquillo, D., Kordas, K., Rojas, O., Alatorre, J., Lopez, P., Garcia-Vargas, G., del Carmen Caamaño, M., Cebrián, M. E., & Stoltzfus, R. J. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.9961 · Cited by 357
Metadata
- Authors
- Miller, D. T., Paschal, D. C., Gunter, E. W., Stroud, P. E., & D'Angelo, J.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1987
- Volume
- 112
- Issue
- 12
- Pages
- 1701
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2028650020
- Cited by
- 199
- References
- 0
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier. https://app.cochat.ai/papers/10.1039/an9871201701
- The paper
- Miller, D. T., Paschal, D. C., Gunter, E. W., Stroud, P. E., & D'Angelo, J. (1987). Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier. The Analyst. https://doi.org/10.1039/an9871201701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.