Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record.

Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier

Miller, Dayton T., Paschal, Daniel C., Gunter, Elaine W., Stroud, Phillip E., D'Angelo, Joseph · 1987 · The Analyst

Abstract

Accuracy in the determination of blood lead is of primary importance in such diverse activities as screening for childhood lead poisoning, occupational exposure monitoring and population surveys. To meet the stringent requirements of the third National Health and Nutrition Examination Survey (NHANES III), a large normative population study to be held from 1988–1994, we needed a method for the determination of lead in blood that was simple, accurate, rugged and of defined accuracy for both calibration and control materials. The recent availability of the National Bureau of Standards Standard Reference Materials 2121–2 and 955, a lead standard solution (10 000 mg l–1) and a certified lead in blood reference material has made it possible to evaluate a method against definitive values and NBS reference materials.In the proposed method, sample preparation consists of a simple dilution (1 + 9) with a matrix modifier which contains 0.5%V/V Triton X-100, 0.2%V/V 16 M nitric acid and 0.2%m/V dibasic ammonium phosphate. This matrix modifier stabilises lead so that the majority of the blood matrix may be removed during the char step. Maximum accuracy in dilution is achieved with the use of autopipettes which have been shown to deliver viscous materials such as blood and serum with high accuracy. The method described in this study has a detection limit of about 0.07 µmol l–1(3 SD) and a precision and accuracy of ±2–5% at the 0.24–2.4 µmol l–1 concentration level. Linearity has been demonstrated up to about 4 µmol l–1. Comparability has been established with the previous blood lead analytical method used in other surveys via the analysis of 435 specimens by both the previous (modified Delves cup) and proposed methods. The equation of the resulting line is [ETA-AAS]= 1.0007[Delves]– 0.051, r= 0.924.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/an9871201701

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Miller, D. T., Paschal, D. C., Gunter, E. W., Stroud, P. E., & D'Angelo, J.
Venue
The Analyst
Published
1987
Volume
112
Issue
12
Pages
1701
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2028650020
Cited by
199
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier. https://app.cochat.ai/papers/10.1039/an9871201701
The paper
Miller, D. T., Paschal, D. C., Gunter, E. W., Stroud, P. E., & D'Angelo, J. (1987). Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifier. The Analyst. https://doi.org/10.1039/an9871201701

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.