The DOI matches its Crossref record.
Fibre optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol–gel derived porous coatings
Abstract
A simple, low-cost technique for the fabrication of optical sensors for oxygen is described and preliminary results obtained using these sensors are reported. The technique is based on coating a declad portion of an optical fibre with a microporous glass film prepared by the sol–gel process. A ruthenium complex [RuII–tris-(2,2′-bipyridine) or RuII–tris(4,7-diphenyl-1,10-phenanthroline)] is trapped in the nanometre-scale cage-like structure of the porous film. In this sensor configuration the complex is excited by the evanescent field of the 488 nm radiation guided by the optical fibre. The luminescence from such complexes is known to be quenched by oxygen and the sensors exhibit repeatable quenching behaviour when exposed to various concentrations of oxygen. The ratio R=I0/I100 where I0 and I100 represent the detected signals from a sensor exposed to 100% nitrogen and 100% oxygen, respectively, is used as a measure of the sensitivity of the sensor. Sensors based on the diphenylphenanthroline complex exhibit greater sensitivity than those based on the bipyridine complex, in accordance with theoretical predictions. More importantly, however, the design potential of the sol–gel process for sensor fabrication is demonstrated by the achievement of a substantial increase in R when the process parameters are adjusted to increase the pore volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
An overview of the intelligent packaging technologies in the food sector
Ghaani, M., Cozzolino, C. A., Castelli, G., & Farris, S. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2016.02.008 · Cited by 664
Indicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Block Copolymer−Ceramic Hybrid Materials from Organically Modified Ceramic Precursors
Simon, P. F. W., Ulrich, R., Spiess, H. W., & Wiesner, U. (2001) · Chemistry of Materials · doi:10.1021/cm0110674 · Cited by 261
Metadata
- Authors
- MacCraith, B. D., McDonagh, C. M., O'Keeffe, G., Keyes, E. T., Vos, J. G., O'Kelly, B., & McGilp, J. F.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1993
- Volume
- 118
- Issue
- 4
- Pages
- 385-388
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2018199255
- Cited by
- 215
- References
- 0
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fibre optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol–gel derived porous coatings. https://app.cochat.ai/papers/10.1039/an9931800385
- The paper
- MacCraith, B. D., McDonagh, C. M., O'Keeffe, G., Keyes, E. T., Vos, J. G., O'Kelly, B., & McGilp, J. F. (1993). Fibre optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol–gel derived porous coatings. The Analyst. https://doi.org/10.1039/an9931800385
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.