All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contact

Bobacka, Johan, McCarrick, Mary, Lewenstam, Andrzej, Ivaska, Ari·1994·The Analyst

Abstract

All-solid-state ion-selective electrodes were prepared by using poly(3-octylthiophene)(POT) as solid contact material. A film of POT (thickness approximately 0.25 µm) was deposited on a solid substrate (platinum, gold or glassy carbon) by electrochemical polymerization of 3-octylthiophene. The POT layer was subsequently coated with an ion-selective membrane (ISM) to produce a solid-contact ion-selective electrode (SCISE), SCISEs for several ions (Li+, Ca2+ and Cl–) were prepared and investigated. The compositions of the ion-selective membranes were the same as normally used for the same ions in poly(vinyl chloride)(PVC)-based ion-selective electrodes (ISEs) with internal filling solution. The potentiometric response of the SCISEs was studied and compared with that of coated-wire electrodes (CWEs) prepared by coating the bare substrate with the same ion-selective membrane. The potentiometric slopes, limits of detection and response times of the SCISEs were similar to those of the corresponding CWEs, but the long-term stability of the potential was different for the two type of electrodes. The SCISEs exhibited a more stable electrode potential than the corresponding CWEs. However, the stability of the SCISEs was found to be influenced by the substrate material and this was studied in detail for the Ca-SCISE and Ca-CWE. For comparison, a Ca-ISE with internal filling solution was also used. By using glassy carbon as the substrate it was possible to obtain a Ca-SCISE exhibiting a standard potential that was almost as stable (ESCISE= 259.3 ± 1.3 mV, drift = 0.23 mV d–1) as for the conventional Ca-ISE (EISE= 61.4 ± 0.5 mV, drift = 0.16 mV d–) and significantly more stable than for the Ca-CWE, during a time period of 8 d. The most stable Ca-CWE, prepared by using glassy carbon as substrate, showed a potential drift of –3.8 mV d–1(ECWE= 269.6 ± 10.2 mV) during testing for 8 d. Electrochemical impedance spectrometry was used to understand the charge-transfer mechanisms of the different types of ion-selective electrodes studied. The impedance response of the electrodes was modelled by equivalent electrical circuits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/an9941901985

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Bobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A.
Venue
The Analyst
Published
1994
Volume
119
Issue
9
Pages
1985
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2105207493
Cited by
175
References
0
FWCI
1.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contact. https://app.cochat.ai/papers/10.1039/an9941901985
The paper
Bobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994). All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contact. The Analyst. https://doi.org/10.1039/an9941901985

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.