The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Potentiometric Ion Sensors Based on Conducting Polymers
Open accessAbstract
Conducting polymers (electroactive conjugated polymers, ECPs) have emerged as one of the most promising transducers for chemical sensors. This is related to the unique electrical, electrochemical and optical properties of conjugated polymers that can be used to convert chemical information (concentration, activity, partial pressure) into electrical or optical signals in the solid state. Application of conjugated polymers in potentiometric ion sensors (ion‐selective electrodes, ISEs) is reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supramolecular Chemistry: Concepts and Perspectives
Lehn, J. (1995) · Wiley eBooks · doi:10.1002/3527607439 · Cited by 9,864
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Synthesis of electrically conducting organic polymers: halogen derivatives of polyacetylene, (CH) x
Shirakawa, H., Louis, E. J., MacDiarmid, A. G., Chiang, C. K., & Heeger, A. J. (1977) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39770000578 · Cited by 3,867
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
High-Resolution Inkjet Printing of All-Polymer Transistor Circuits
Sirringhaus, H., Kawase, T., Friend, R. H., Shimoda, T., Inbasekaran, M., Wu, W., & Woo, E. P. (2000) · Science · doi:10.1126/science.290.5499.2123 · Cited by 3,311
Handbook of organic conductive molecules and polymers
Nalwa, H. S. (1997) · Cited by 2,786
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Handbook of advanced electronic and photonic materials and devices
Nalwa, H. S. (2001) · Cited by 1,220
The Molecular Wire Approach to Sensory Signal Amplification
Swager, T. M. (1998) · Accounts of Chemical Research · doi:10.1021/ar9600502 · Cited by 1,139
Paul, E. W., Ricco, A. J., & Wrighton, M. S. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100254a028 · Cited by 1,026
Cited by
Conducting polymers in chemical sensors and arrays
Lange, U., Roznyatovskaya, N. V., & Mirsky, V. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.02.068 · Cited by 911
Combinatorial and High-Throughput Screening of Materials Libraries: Review of State of the Art
Potyrailo, R., Rajan, K., Stoewe, K., Takeuchi, I., Chisholm, B., & Lam, H. (2011) · ACS Combinatorial Science · doi:10.1021/co200007w · Cited by 511
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Star-shaped π-conjugated oligomers and their applications in organic electronics and photonics
Kanibolotsky, A. L., Perepichka, I. F., & Skabara, P. J. (2010) · Chemical Society Reviews · doi:10.1039/b918154g · Cited by 366
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Metadata
- Authors
- Bobacka, J., Ivaska, A., & Lewenstam, A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 15
- Issue
- 5-6
- Pages
- 366-374
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2094719083
- Cited by
- 277
- References
- 67
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Potentiometric Ion Sensors Based on Conducting Polymers. https://app.cochat.ai/papers/10.1002/elan.200390042
- The paper
- Bobacka, J., Ivaska, A., & Lewenstam, A. (2003). Potentiometric Ion Sensors Based on Conducting Polymers. Electroanalysis. https://doi.org/10.1002/elan.200390042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.