CoChat

Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds

Peng, Chiung-Yu, Batterman, Stuart · 2000 · Journal of Environmental Monitoring
Cited by 96

The DOI matches its Crossref record.

Abstract

Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b003385p

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
Peng, C.-Y., & Batterman, S.
Venue
Journal of Environmental Monitoring
Published
2000
Volume
2
Issue
4
Pages
313-324
ISSN
  • 1464-0325 (ISSN-L)
  • 1464-0333
OpenAlex
W1981392314
Cited by
96
References
0
FWCI
2.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds. https://app.cochat.ai/papers/10.1039/b003385p
The paper
Peng, C.-Y., & Batterman, S. (2000). Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds. Journal of Environmental Monitoring. https://doi.org/10.1039/b003385p

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.