The DOI matches its Crossref record.
Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: verification and application of optimized analytical protocols
Abstract
Previous studies have demonstrated the potential of multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for precise Pb isotopic measurements using admixed Tl for 'external normalization' of instrumental mass discrimination. The Micromass IsoProbe is a new, single-focusing MC-ICP-MS instrument that does not employ an electrostatic sector for energy-focusing. Instead, a hexapole collision cell is used to thermalize the ion beam. This study presents the first in-depth investigation of the application of the IsoProbe to Pb isotope ratio measurements. With a Tl-based mass bias correction, multiple analyses of mixed Pb–Tl standard solutions typically display reproducibilities (±2σ) of about 50 ppm for 207Pb∶206Pb, 100 ppm for 208Pb∶206Pb and 206Pb∶204Pb, 150 ppm for 207Pb∶204Pb and 175 ppm for 208Pb∶204Pb. Using an empirically optimized exponential law normalization, the Pb isotope data show excellent agreement with reference values obtained by thermal ionization mass spectrometry. The cross-calibration between NIST SRM 981 and 982 demonstrates that accurate results can be obtained with this technique over a wide range of Pb isotopic compositions. The Tl-corrected Pb data obtained on the IsoProbe, however, display correlations with the Pb∶Tl ratio of the analyzed solutions. The addition of large amounts of Tl to the samples is unfavorable for the accurate measurement of the low-intensity 204Pb ion beam. Analytical artifacts may also be generated if high concentrations of concomitant elements are present in the sample solutions. Matrix effects and instrumental memory, however, can be readily overcome by the adoption of appropriate analytical protocols and it is demonstrated that sample measurements can achieve the same levels of precision and accuracy as are routinely obtained for analyses of pure standard solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Precise and accurate isotopic measurements using multiple-collector ICPMS
Albarède, F., Telouk, P., Blichert-Toft, J., Boyet, M., Agranier, A., & Nelson, B. (2004) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2003.11.024 · Cited by 570
Galy, A., Yoffe, O., Janney, P. E., Williams, R. W., Cloquet, C., Alard, O., Halicz, L., Wadhwa, M., Hutcheon, I. D., Ramon, E., et al. (2003) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b309273a · Cited by 463
Thirlwall, M. F. (2002) · Chemical Geology · doi:10.1016/s0009-2541(01)00365-5 · Cited by 325
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324
Wombacher, F., Rehkämper, M., Mezger, K., & Münker, C. (2003) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(03)00389-2 · Cited by 266
Self-citationArcher, C., & Vance, D. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b315853e · Cited by 265
Stephens, J., Killick, D., & Chirikure, S. (2023) · PLOS ONE · doi:10.1371/journal.pone.0282660 · Cited by 14
Metadata
- Authors
- Rehkämper, M., & Mezger, K.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 15
- Issue
- 11
- Pages
- 1451-1460
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W1972954480
- Cited by
- 186
- References
- 0
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.