The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes
Abstract
Multiple-collector magnetic sector ICP-MS affords the possibility of applying instrumental mass discrimination corrections using a reference isotope ratio of an element (dopant) other than the analyte. Much attention has focused on the use of this approach for lead isotope analysis using a thallium dopant and the technique has also been applied to copper–zinc isotope analysis. The most successful applications of the doping approach have established empirical mass bias relationships between dopant and analyte isotope ratios but this often has to be done for single analytical sessions. Insufficient intra-session variation in mass discrimination often leads to poor constraints on these relationships. Moreover, with the Tl–Pb system there is some doubt over whether samples and standards exhibit the same relationship. Here we show that for the Cu–Zn system, two improvements on previous approaches lead to precise and accurate isotope ratios for unknowns. Firstly, addition of Sr to mixed Cu–Zn standard solutions generates extreme variation in mass bias so that empirical mass bias relationships between analyte and dopant are much better constrained. Secondly, we show that inadequate chemistry, specifically the inefficient removal of matrix Fe and Ti, seriously compromises the Cu–Zn isotope analysis of samples but that with clean chemistry, samples with complex matrices demonstrably yield similar mass discrimination relationships between Cu and Zn isotopes to standards. We also document previously unreported aspects of Cu–Zn isotope analysis: (1) that Cu–Zn mass bias relationships depend critically on the Cu/Zn ratio of the solution; (2) that for an introduction system with a desolvating membrane, the behaviour of standards is highly variable, perhaps due to variations in the oxidation state of Cu in the solution, and that this can be overcome by the passage of standards through the ion exchange procedure used to purify samples. Finally, we document chemical separation and mass spectrometric techniques that permit the isotopic analysis of order of magnitude smaller samples than previously achieved and report values for BCR-1 basalt standard of δ66Zn = 0.20 ± 0.09‰ (n = 12) and δ65Cu = 0.07 ± 0.08‰ (n = 6) at the 95% confidence level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry
Maréchal, C. N., Télouk, P., & Albarède, F. (1999) · Chemical Geology · doi:10.1016/s0009-2541(98)00191-0 · Cited by 1,360
Precise determination of SmNd ratios, Sm and Nd isotopic abundances in standard solutions
Wasserburg, G. J., Jacobsen, S. B., DePaolo, D. J., McCulloch, M. T., & Wen, T. (1981) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(81)90085-5 · Cited by 940
Application of Fe isotopes to tracing the geochemical and biological cycling of Fe
Beard, B. L., Johnson, C. M., Skulan, J. L., Nealson, K. H., Cox, L., & Sun, H. (2003) · Chemical Geology · doi:10.1016/s0009-2541(02)00390-x · Cited by 611
High-precision analysis of Pb isotope ratios by multi-collector ICP-MS
White, W. M., Albarède, F., & Télouk, P. (2000) · Chemical Geology · doi:10.1016/s0009-2541(99)00182-5 · Cited by 568
Mass fractionation processes of transition metal isotopes
Zhu, X. K., Guo, Y., Williams, R. J. P., O’Nions, R. K., Matthews, A., Belshaw, N. S., Canters, G. W., de Waal, E. C., Weser, U., Burgess, B. K., et al. (2002) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(02)00615-5 · Cited by 487
Belshaw, N. S., Freedman, P. A., O’Nions, R. K., Frank, M., & Guo, Y. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14150-7 · Cited by 332
Zhu, X., O'Nions, R. K., Guo, Y., Belshaw, N. S., & Rickard, D. T. (2000) · Chemical Geology · doi:10.1016/s0009-2541(99)00076-5 · Cited by 327
Thirlwall, M. F. (2002) · Chemical Geology · doi:10.1016/s0009-2541(01)00365-5 · Cited by 325
Pichat, S., Douchet, C., & Albarède, F. (2003) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(03)00106-7 · Cited by 293
Thirlwall, M. F. (2000) · Chemical Geology · doi:10.1016/s0009-2541(99)00135-7 · Cited by 274
Cited by
Urban environmental geochemistry of trace metals
Wong, C. S. C., Li, X., & Thornton, I. (2006) · Environmental Pollution · doi:10.1016/j.envpol.2005.09.004 · Cited by 600
Little, S. H., Vance, D., Walker-Brown, C., & Landing, W. M. (2014) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2013.07.046 · Cited by 353
Self-citationMo isotope fractionation during adsorption to Fe (oxyhydr)oxides
Goldberg, T., Archer, C., Vance, D., & Poulton, S. W. (2009) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2009.08.004 · Cited by 329
Self-citationBalistrieri, L. S., Borrok, D. M., Wanty, R. B., & Ridley, W. I. (2008) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2007.11.013 · Cited by 323
The isotopic signature of the global riverine molybdenum flux and anoxia in the ancient oceans
Archer, C., & Vance, D. (2008) · Nature Geoscience · doi:10.1038/ngeo282 · Cited by 292
Self-citation
Metadata
- Authors
- Archer, C., & Vance, D.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 19
- Issue
- 5
- Pages
- 656
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2007256017
- Cited by
- 265
- References
- 24
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes. https://app.cochat.ai/papers/10.1039/b315853e
- The paper
- Archer, C., & Vance, D. (2004). Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b315853e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.