CoChat

Redox state and mobility of iron at the asbestos surface: a voltammetric approach

Prandi, Laura, Bodoardo, Silvia, Penazzi, Nerino, Fubini, Bice · 2001 · Journal of Materials Chemistry
Cited by 18

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The mechanism by which asbestos causes the development of cancer in people exposed to airborne fibres, still unclear at the molecular level, seems to involve iron ions located at particular sites at the fibre surface. In this paper, cyclic voltammetry has been employed to investigate the oxidation state and mobility of iron ions on crocidolite and amosite, the two most common types of amphibole asbestos. Experiments have been carried out at three pH values: 0.5, at which iron is spontaneously released from the solids; neutral (close to the extracellular and cytoplasmatic value); and 4.5, representative of the lysosomial fluid, i.e. of the environment to which a phagocytized fibre is exposed. An Fe-exchanged Y zeolite and an Fe-silicalite have been used for comparison as ‘model solids’. At neutral pH iron is readily mobilised from FeY upon cycling, in contrast with Fe-silicalite. With both asbestos materials, at neutral pH iron is mobilised during the subsequent cycles and is brought into solution, amosite releasing more iron than crocidolite per unit area under the same conditions. Three couples of redox peaks are seen, centred at ca. 0.0, −0.2 and +0.6 V. The first is due to the Fe3+/Fe2+ couple in solution, the second is probably related to the Fe3+/Fe2+ at the surface of the asbestos particle, and the third is assigned to surface iron in an oxidation state higher than three. At pH 0.5, the couple of peaks due to surface Fe is absent and mobilisation immediately occurs. The release of iron at pH 0.5 from asbestos was also measured photometrically and, in the first two hours, corresponds to that expected for the outermost layer of the minerals. Voltammetric cycling markedly enhances the amount of Fe solubilised. Partial oxidation or reduction of surface iron ions was obtained by keeping the sample at a defined potential before cycling: subsequent voltammograms indicate that the smaller Fe3+ cation is the mobilised species.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b005714m

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 18

Metadata

Authors
Prandi, L., Bodoardo, S., Penazzi, N., & Fubini, B.
Venue
Journal of Materials Chemistry
Published
2001
Volume
11
Issue
5
Pages
1495-1501
ISSN
  • 0959-9428 (ISSN-L)
  • 1364-5501
OpenAlex
W2040725452
Cited by
18
References
7
FWCI
1.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.