Chromatographic methods for the determination of the logL16 solute descriptor
The DOI matches its Crossref record.
Abstract
A squalane packed column and two open-tubular columns coated with an immobilized stationary phase film of poly(dimethylsiloxane) or poly(methyloctylsiloxane) are evaluated as surrogate chromatographic systems for the determination of the logL16 solute descriptor by gas chromatography. Retention on the squalane column is dominated by gas-liquid partitioning with a significant temperature-dependent contribution from interfacial adsorption at the liquid-solid interface. Using the gas-liquid partition coefficient as the dependent model variable allows logL16 to be estimated to +/- 0.026 log units over the temperature range 60-120 degrees C. Without correction for interfacial adsorption a single column estimation of logL16 with phase loadings of 8 to 20% (m/m) over the temperature range 80-120 degrees C is possible for compounds with moderate hydrogen-bond basicity. The poly(dimethylsiloxane) stationary phase is both dipolar and hydrogen-bond basic and less suitable than the poly(methyloctylsiloxane) stationary phase, which is less cohesive and has similar dipolarity but no hydrogen-bond basicity. The determination of logL16 on the poly(methyloctylsiloxane) column requires prior knowledge of the solute dipolarity/polarizability descriptor to avoid significant errors in the measurement of logL16 for polar compounds. In such circumstances a single column estimation of logL16 over the temperature range 60-140 degrees C with an error of +/- 0.05-0.09 log units is possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determination of sets of solute descriptors from chromatographic measurements
Abraham, M. H., Ibrahim, A., & Zissimos, A. M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.12.004 · Cited by 891
Poole, C. F., Ariyasena, T. C., & Lenca, N. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.05.045 · Cited by 180
Self-citationFoundations of retention in partition chromatography
Poole, C. F., & Poole, S. K. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.092 · Cited by 111
Self-citationHammer, J., & Endo, S. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.2c05804 · Cited by 58
Metadata
- Authors
- Li, Q., Poole, C. F., Kiridena, W., & Koziol, W. W.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 125
- Issue
- 12
- Pages
- 2180-2188
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2004225347
- Cited by
- 55
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chromatographic methods for the determination of the logL16 solute descriptor. https://app.cochat.ai/papers/10.1039/b006380k
- The paper
- Li, Q., Poole, C. F., Kiridena, W., & Koziol, W. W. (2000). Chromatographic methods for the determination of the logL16 solute descriptor. The Analyst. https://doi.org/10.1039/b006380k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.