Homogeneous liquid–liquid extraction method for the selective spectrofluorimetric determination of trace amounts of tryptophan
The DOI matches its Crossref record.
Abstract
Twenty-one amino acids were derivatized with fluorescamine (FLA) under basic conditions (pH 9) and the extraction of the amino acid-FLA derivatives was investigated using a homogeneous liquid-liquid extraction with perfluorooctanoic acid (HPFOA) based on phase separation under strongly acidic conditions. Under the optimum concentration conditions for the reagents ([PFOA]T = 3 x 10(-3) mol dm-3, [acetone]T = 3 vol.%, [HCl]T = 1.8 mol dm-3), the concentration factor was approximately 1000-fold (i.e., 30 microliters of the sedimented liquid phase was produced from 33 ml of the homogeneous aqueous solution). The percentage extraction (E) was determined for the 21 amino acid-FLA derivatives; the value for the tryptophan (Trp)-FLA derivative was 80.9%, whereas the other derivatives were not almost extracted (E < 0.4%). The Trp-FLA derivative was selective for the extraction using the homogeneous liquid-liquid extraction method with HPFOA. After the sedimented liquid phase containing Trp-FLA has been placed on a polytetrafluoroethylene filter-paper, the fluorescence intensity was determined using a spectrofluorimeter with filter-paper as the solid-sample holder. The calibration graph of Trp was linear over the range 1.0 x 10(-8)-1.5 x 10(-6) mol dm-3. The relative standard deviation for the central value of the calibration graph was 4.5% (five determinations) and the detection limit (S/N = 3) was 8.9 x 10(-9) mol dm-3. When the proposed method was applied to the highly sensitive spectrofluorimetric determination of Trp in animalin-L syrup, the results were satisfactory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Fattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.002 · Cited by 178
Saito, S., Ohno, O., Igarashi, S., Kato, T., & Yamaguchi, H. (2015) · Metals · doi:10.3390/met5031543 · Cited by 14
Self-citation
Metadata
- Authors
- Oshite, S., Furukawa, M., & Igarashi, S.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 126
- Issue
- 5
- Pages
- 703-706
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2171514142
- Cited by
- 37
- References
- 0
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Homogeneous liquid–liquid extraction method for the selective spectrofluorimetric determination of trace amounts of tryptophan. https://app.cochat.ai/papers/10.1039/b100114k
- The paper
- Oshite, S., Furukawa, M., & Igarashi, S. (2001). Homogeneous liquid–liquid extraction method for the selective spectrofluorimetric determination of trace amounts of tryptophan. The Analyst. https://doi.org/10.1039/b100114k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.