Effect of ultrasonic agitation on the release of copper, iron, manganese and zinc from soil and sediment using the BCR three-stage sequential extraction
The DOI matches its Crossref record.
Abstract
An ultrasonic bath and an ultrasonic probe have been used to develop rapid versions of the three-stage Community Bureau of Reference (BCR, now the Standards, Measurement and Testing Programme) sequential extraction procedure. The effect of the ultrasonic treatments on the extraction of copper, iron, manganese and zinc from a sewage sludge-amended soil has been assessed. Recoveries similar to those of conventional shaking (i.e., conventional value, +/- 30%) could generally be obtained for copper, manganese and zinc, but not for the important matrix element iron. With the use of compromise sonication conditions, steps 1, 2 and 3 of the sequential extraction (excluding the hydrogen peroxide digestion in step 3, which was not performed with sonication) could be completed in 3, 5 and 1 min, respectively, using the ultrasonic probe, and in 3, 1 and 1 h, respectively, using the bath. The extraction procedures developed using the soil performed well when applied to lake sediment BCR CRM 601. Analyte partitioning was generally similar to that obtained with mechanical shaking, and overall metal recoveries were 84-98% of those obtained with the conventional BCR protocol, except for copper extracted with the probe (74%). Poorer performance (analyte recoveries, 58-104%) was obtained when the methods were applied to an intertidal sediment. This highlights the difficulty of developing a version of the BCR extraction, with ultrasonic assistance, which gives a performance equivalent to conventional shaking when applied to different substrates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Is there a future for sequential chemical extraction?
Bacon, J. R., & Davidson, C. M. (2008) · The Analyst · doi:10.1039/b711896a · Cited by 649
Self-citationRao, C. R. M., Sahuquillo, A., & Lopez Sanchez, J. F. (2008) · Water, Air, and Soil Pollution · doi:10.1007/s11270-007-9564-0 · Cited by 538
Kartal, Ş., Aydın, Z., & Tokalıoğlu, Ş. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2005.11.091 · Cited by 318
Arain, M. B., Kazi, T. G., Jamali, M. K., Jalbani, N., Afridi, H. I., & Baig, J. A. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.11.004 · Cited by 191
Fedotov, P. S., Kördel, W., Miró, M., Peijnenburg, W. J. G. M., Wennrich, R., & Huang, P.-M. (2012) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2011.556544 · Cited by 78
“, 2002) or ultrasound (Arain et al., 2008; Davidson and Delevoye, 2001; Greenway and Song, 2002) as auxiliary energies, whereby the overall extraction time has been drastically reduced from days to merely a few minutes or hours.”
Background
Metadata
- Authors
- Davidson, C. M., & Delevoye, G.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 3
- Issue
- 4
- Pages
- 398-403
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W2069676750
- Cited by
- 53
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of ultrasonic agitation on the release of copper, iron, manganese and zinc from soil and sediment using the BCR three-stage sequential extraction. https://app.cochat.ai/papers/10.1039/b103602p
- The paper
- Davidson, C. M., & Delevoye, G. (2001). Effect of ultrasonic agitation on the release of copper, iron, manganese and zinc from soil and sediment using the BCR three-stage sequential extraction. Journal of Environmental Monitoring. https://doi.org/10.1039/b103602p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.