The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
On-chip culture system for observation of isolated individual cells
Abstract
To investigate the properties of isolated single cells with their environment, we developed the differential analysis method for single cells using an on-chip microculture system. The advantages of the system are, (i). continuous cultivation of a series of isolated single cells or a group of cells under contamination free conditions, (ii). continuous observation and comparison of those cells with 0.2 microm spatial resolution by a phase-contrast/fluorescent microscopy system with digital image processing. The core of the system is an n x n (n = 20-50) array of chambers, where each is 20-70 microm in diameter and 5-30 microm deep holes etched into a biotin-coated 0.17 mm thick glass slide. The biotin-coated glass slide is covered with the streptavidin coated cellulose semipermeable membrane, which is fixed on the surface of the glass slide by streptavidin-biotin attachment, separating those holes from the nutrient medium circulating through a 'cover chamber' above. A single cell or group of cells can thus be isolated from environment perfused with the same medium, and the medium in each chamber can be changed within the diffusion time (<1/30 s). In addition, the microchamber volumes of specific cells or cell groups can be controlled by the sizes of the chambers. By using this system we found that the length of isolated Escherichia coli increased at 0.06 microm min(-1) between cell divisions regardless of the chamber volume, and that the cell concentration reached 10(12) cells ml(-1) under contamination free conditions. The system is thus particularly useful for one cell level analysis because the direct descendants of single cells can be cultured and compared in the isolated microchambers, and the physical properties of the cells in each microchamber can be continuously observed and compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Wilkinson, D. W. (1987) · doi:10.1242/dev.99.3.439 · Cited by 418
Cited by
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Microfluidic sorting of mammalian cells by optical force switching
Wang, M. M., Tu, E., Raymond, D. E., Yang, J. M., Zhang, H., Hagen, N., Dees, B., Mercer, E. M., Forster, A. H., Kariv, I., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1050 · Cited by 690
Where microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Large-Scale Single-Cell Trapping And Imaging Using Microwell Arrays
Rettig, J. R., & Folch, A. (2005) · Analytical Chemistry · doi:10.1021/ac0505977 · Cited by 502
Metadata
- Authors
- Inoue, I., Wakamoto, Y., Moriguchi, H., Okano, K., & Yasuda, K.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 1
- Issue
- 1
- Pages
- 50
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2139891988
- Cited by
- 185
- References
- 2
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.