The DOI matches its Crossref record.
A fluorescent PEBBLE nanosensor for intracellular free zinc
Abstract
The development and characterisation of a fluorescent optical PEBBLE (Probe Encapsulated By Biologically Localised Embedding) nanosensor for the detection of zinc is detailed. A ratiometric sensor has been fabricated that incorporates two fluorescent dyes; one is sensitive to zinc and the other acts as a reference. The sensing components are entrapped within a polymer matrix by a microemulsion polymerisation process that produces spherical sensors that are in the size region of 20 to 200 nm. Cellular measurements are made possible by the small sensor size and the biocompatibility of the matrix. The effects of reversibility, photobleaching and leaching have been examined, as well as the selectivity towards zinc over other cellular ions such as Na+, Ca2+, K+, and Mg2+. The dynamic range of these sensors was found to be 4 to 50 microM Zn2+ with a linear range from 15 to 40 microM. The response time for the PEBBLE is less than 4 s and the sensor is reversible. In addition, the nanosensors are photostable and leaching from the matrix, determined using a novel method, is minimal. These sensors are capable of real-time inter- and intra-cellular imaging and are insensitive to interference from proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Nanotech approaches to drug delivery and imaging
Sahoo, S. K., & Labhasetwar, V. (2003) · Drug Discovery Today · doi:10.1016/s1359-6446(03)02903-9 · Cited by 1,203
Jiang, P., & Guo, Z. (2004) · Coordination Chemistry Reviews · doi:10.1016/j.cct.2003.10.013 · Cited by 989
Implications of Nanobiosensors in Agriculture
Rai, V., Acharya, S., & Dey, N. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322039 · Cited by 332
Metadata
- Authors
- Sumner, J. P., Aylott, J. W., Monson, E., & Kopelman, R.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001-12-04
- Volume
- 127
- Issue
- 1
- Pages
- 11-16
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2022130063
- Cited by
- 160
- References
- 0
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fluorescent PEBBLE nanosensor for intracellular free zinc. https://app.cochat.ai/papers/10.1039/b108568a
- The paper
- Sumner, J. P., Aylott, J. W., Monson, E., & Kopelman, R. (2002). A fluorescent PEBBLE nanosensor for intracellular free zinc. The Analyst. https://doi.org/10.1039/b108568a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.