CoChat

An evaporation-based microfluidic sample concentration method

Walker, Glenn M., Beebe, David J. · 2002 · Lab on a Chip
Cited by 106

The DOI matches its Crossref record.

Abstract

We present a method for sample concentration within microfluidic devices using evaporation-induced flow. Evaporation-induced flow is easy to incorporate into microfluidic designs and can be used to concentrate a wide variety of molecules. The practicality of this method was demonstrated with 0.2 microm fluorescent spheres and FITC-labeled BSA. Thirty two percent of the 0.6 microL fluorescent sphere suspension was concentrated into a well within a microfluidic device. In the same amount of time, 93% of the 0.6 microL FITC-labeled BSA solution was concentrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b202473j

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 106

Metadata

Authors
Walker, G. M., & Beebe, D. J.
Venue
Lab on a Chip
Published
2002
Volume
2
Issue
2
Pages
57
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2101651250
Cited by
106
References
0
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An evaporation-based microfluidic sample concentration method. https://app.cochat.ai/papers/10.1039/b202473j
The paper
Walker, G. M., & Beebe, D. J. (2002). An evaporation-based microfluidic sample concentration method. Lab on a Chip. https://doi.org/10.1039/b202473j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.