The DOI matches its Crossref record.
Raman spectroscopy for identification of epithelial cancers
Abstract
There is a real need for improvements in cancer detection. Significant problems are encountered when utilising the gold standard of excisional biopsy combined with histopathology. This can include missed lesions, perforation and high levels of inter- and intra-observer discrepancies. The clinical requirements for an objective, non-invasive real time probe for accurate and repeatable measurement of tissue pathological state are overwhelming. This study has evaluated the potential for Raman spectroscopy to achieve this goal. The technique measures the molecular specific inelastic scattering of laser light within tissue, thus enabling the analysis of biochemical changes that precede and accompany disease processes. Initial work has been carried out to optimise a commercially available Raman microspectrometer for tissue measurements; to target potential malignancies with a clinical need for diagnostic improvements (oesophagus. colon, breast, andd prostate) and to build and test spectral libraries and prediction algorithms for tissue types and pathologies. This study has followed rigorous sample collection protocols and histopathological analysis using a board of expert pathologists. Only the data from samples with full agreement of a homogeneous pathology have been used to construct a training data set of Raman spectra. Measurements of tissue specimens from the full spectrum of different pathological groups found in each tissue have been made. Diagnostic predictive models have been constructed and optimised using multivariate analysis techniques. They have been tested using cross-validation or leave-one-out and demonstrated high levels of discrimination between pathology groups (greater than 90% sensitivity and specificity for all tissues). However larger sample numbers are required for further evaluation. The discussions outline the likely work required for successful implementation of in vivo Raman detection of early malignancies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Self-citationAdvances in Fourier transform infrared (FTIR) spectroscopy of biological tissues
Talari, A. C. S., Martinez, M. A. G., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1230863 · Cited by 533
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Erzina, M., Trelin, A., Guselnikova, O., Dvorankova, B., Strnadova, K., Perminova, A., Ulbrich, P., Mares, D., Jerabek, V., Elashnikov, R., et al. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.127660 · Cited by 116
Metadata
- Authors
- Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H.
- Venue
- Faraday Discussions
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 126
- Pages
- 141
- ISSN
- 1359-6640 (ISSN-L)
- 1364-5498
- OpenAlex
- W1977182656
- Cited by
- 768
- References
- 0
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman spectroscopy for identification of epithelial cancers. https://app.cochat.ai/papers/10.1039/b304992b
- The paper
- Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H. (2004). Raman spectroscopy for identification of epithelial cancers. Faraday Discussions. https://doi.org/10.1039/b304992b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.