Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 282

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS

Guillong, M., Horn, I., Günther, D. · 2003 · J. Anal. At. Spectrom.

Abstract

Laser ablation using wavelengths of 266 nm, 213 nm and 193 nm as a sampling method for ICP-MS was compared. Unlike previous studies, this was performed under essentially identical laser ablation conditions with the exception of wavelength. This was achieved by using a single solid state laser source (1064 nm Nd:YAG) for harmonic generation together with sum frequency mixing and optical parametric oscillation. Experiments were carried out on the NIST 600 series silicate glasses. Particle size distributions for all three wavelength were measured and increased in the order 193 nm < 213 nm < 266 nm. This effect is related to the absorption behaviour of the sample opaque < transparent at each wavelength. The change towards larger particle sizes with increasing wavelength is influencing the noise in the transient signals and their intensity ratios. A smaller number of particles with diameters of >150 nm are produced in comparison to longer wavelengths when ablating with 193 nm. Due to the decreased amount of particles above 0.15 µm vaporisation induced elemental fractionation within the ICP, especially for more transparent samples is reduced. Data on the behaviour of 213 nm ablation and resulting ICP-MS response demonstrated that this wavelength is intermediate between 193 nm and 266 nm, but biased towards 193 nm for more opaque samples and biased towards 266 nm for those more transparent. This study (maintaining laser parameter constant and not exceeding depth to diameter ratios of 2∶1) shows that the wavelengths in first instance are responsible for particle size distribution and that their distribution leads to enhanced vaporisation, atomisation and ionisation effects within the ICP. Until now, only 193 nm produced particle sizes (as shown for the selection of silicate samples) can be stoichiometrically converted into ions using common ICP-MS instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b305434a

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Guillong, M., Horn, I., & Günther, D.
Venue
J. Anal. At. Spectrom.
Published
2003
Volume
18
Issue
10
Pages
1224-1230
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2104846889
Cited by
282
References
13
FWCI
24.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.