Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 402

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier

Günther, Detlef, A. Heinrich, Christoph·1999·J. Anal. At. Spectrom.

Abstract

Laser ablation-ICP-MS is a sensitive and accurate technique for major to trace multi-element analysis at high spatial resolution on the scale of 10 µm. A wide variety of samples can be studied quantitatively, including minerals and their solid, liquid or melt inclusions as required for geochemical studies. As the desired spatial resolution increases, however, detection limits become severely constrained by the total amount of sample material reaching the ICP. Detection limits are therefore determined by the ablation rate and by the efficiency of removal of ablated aerosol particles from the ablation spot and their transport into the plasma. Properties of the carrier gas are known to affect the ablation process and the efficiency of particle transportation. This study explores the effects of different ablation-cell configurations and the use of helium, dry argon and argon moistened with water for the transport of aerosols into an ICP-MS, using a prototype 193 nm ArF excimer laser. Deposition of visible particles deposited around the ablation pit is significantly reduced when helium is used instead of argon. A moderate flux of helium through the chamber, mixed with moistened argon immediately downstream from the ablation chamber, leads to at least a 2-3-fold increase in the signal intensities across the entire mass range when compared with argon gas only. Background intensities above mass 85 are significantly reduced, but polyatomic interferences in the low mass region increase by an order of magnitude, owing to oxide formation caused by the water load. A high flux of helium, mixed just behind the ablation cell with dry argon, yields a 2-3-fold sensitivity enhancement, in addition to greatly reduced background intensity across the entire mass range. This results in one order of magnitude improvement in detection limits for most elements. These modifications permit the routine determination of minor concentrations of chlorine in microscopic fluid inclusions or the analysis of minerals, such as trace element concentrations in quartz (e.g., Na and Li down to 500 ng g –1 , using a 40 µ ablation pit). Furthermore, this improved sensitivity has recently yielded the first quantitative determination of gold concentrations (∼0.1 µg g –1 ) and full rare-earth element patterns in single 25 µm fluid inclusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/a901648a

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 402

Metadata

Authors
Günther, D., & A. Heinrich, C.
Venue
J. Anal. At. Spectrom.
Published
1999
Volume
14
Issue
9
Pages
1363-1368
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W1968256284
Cited by
402
References
12
FWCI
19.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier. https://app.cochat.ai/papers/10.1039/a901648a
The paper
Günther, D., & A. Heinrich, C. (1999). Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier. J. Anal. At. Spectrom. https://doi.org/10.1039/a901648a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.