High-precision Cu and Zn isotope analysis by plasma source mass spectrometry
The DOI matches its Crossref record.
Abstract
Two approaches to correct for mass discrimination effects associated with Cu and Zn isotopic measurements on two different MC-ICP-MS instruments (a Micromass IsoProbe and a VG Axiom) have been compared and assessed in detail: (1) sample-standard bracketing (SSB), and (2) the ‘empirical external normalisation’ (EEN) whereby a second element is used to simultaneously correct for mass discrimination. This has provided new insights into the mass discrimination behaviours of Cu and Zn under varying instrumental set-ups, and has allowed improvements to be made to the existing correction procedures. With the SSB approach, mass bias stability is a prerequisite, and matrix components must be removed from the analyte to avoid matrix-related mass discrimination effects. By comparison, the EEN approach requires a degree of mass bias instability, and automatically corrects for matrix-related mass discrimination effects. The EEN correction may therefore appear more robust. However, while the EEN correction yields high-precision 65Cu/63Cu and 66Zn/64Zn data, an as yet unidentified source of systematic drift in the 67Zn and 68Zn signals through time hinders analyses of ratios incorporating these isotopes. Using the EEN correction where analyte and spike ratios were measured sequentially within a peak-switching protocol led to a three-fold deterioration in precision relative to static measurements. This is consistent with mass bias drift on the scale of a single five-second-measurement integration. For relative 65Cu/63Cu and 66Zn/64Zn ratio measurements, the SSB and EEN corrections give long-term reproducibilities of less then ±0.07‰ (2SD) for pure Cu and Zn reagents. This is sufficient for resolving mass-dependent isotopic variability in natural and anthropogenic materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Urban environmental geochemistry of trace metals
Wong, C. S. C., Li, X., & Thornton, I. (2006) · Environmental Pollution · doi:10.1016/j.envpol.2005.09.004 · Cited by 600
The Isotope Geochemistry of Zinc and Copper
Moynier, F., Vance, D., Fujii, T., & Savage, P. (2017) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2017.82.13 · Cited by 407
Little, S. H., Vance, D., Walker-Brown, C., & Landing, W. M. (2014) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2013.07.046 · Cited by 353
Balistrieri, L. S., Borrok, D. M., Wanty, R. B., & Ridley, W. I. (2008) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2007.11.013 · Cited by 323
Accurate and precise determination of isotopic ratios by MC‐ICP‐MS: A review
Yang, L. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20251 · Cited by 285
Metadata
- Authors
- Mason, T. F. D., Weiss, D. J., Horstwood, M., Parrish, R. R., Russell, S. S., Mullane, E., & Coles, B. J.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 19
- Issue
- 2
- Pages
- 218
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2529465186
- Cited by
- 143
- References
- 0
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-precision Cu and Zn isotope analysis by plasma source mass spectrometry. https://app.cochat.ai/papers/10.1039/b306953b
- The paper
- Mason, T. F. D., Weiss, D. J., Horstwood, M., Parrish, R. R., Russell, S. S., Mullane, E., & Coles, B. J. (2004). High-precision Cu and Zn isotope analysis by plasma source mass spectrometry. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b306953b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.