The DOI matches its Crossref record.
Optical tweezers applied to a microfluidic system
Open accessAbstract
We will demonstrate how optical tweezers can be combined with a microfluidic system to create a versatile microlaboratory. Cells are moved between reservoirs filled with different media by means of optical tweezers. We show that the cells, on a timescale of a few seconds, can be moved from one reservoir to another without the media being dragged along with them. The system is demonstrated with an experiment where we expose E. coli bacteria to different fluorescent markers. We will also discuss how the system can be used as an advanced cell sorter. It can favorably be used to sort out a small fraction of cells from a large population, in particular when advanced microscopic techniques are required to distinguish various cells. Patterns of channels and reservoirs were generated in a computer and transferred to a mask using either a sophisticated electron beam technique or a standard laser printer. Lithographic methods were applied to create microchannels in rubber silicon (PDMS). Media were transported in the channels using electroosmotic flow. The optical system consisted of a combined confocal and epi-fluorescence microscope, dual optical tweezers and a laser scalpel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Wang, X., Chen, S., Kong, M., Wang, Z., Costa, K. D., Li, R. A., & Sun, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20653b · Cited by 440
Optical tweezers — from calibration to applications: a tutorial
Gieseler, J., Gomez-Solano, J. R., Magazzù, A., Pérez Castillo, I., Pérez García, L., Gironella-Torrent, M., Viader-Godoy, X., Ritort, F., Pesce, G., Arzola, A. V., et al. (2021) · Advances in Optics and Photonics · doi:10.1364/aop.394888 · Cited by 282
Metadata
- Authors
- Enger, J., Goksör, M., Ramser, K., Hagberg, P., & Hanstorp, D.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 3
- Pages
- 196-200
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2119118682
- Cited by
- 245
- References
- 0
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical tweezers applied to a microfluidic system. https://app.cochat.ai/papers/10.1039/b307960k
- The paper
- Enger, J., Goksör, M., Ramser, K., Hagberg, P., & Hanstorp, D. (2004). Optical tweezers applied to a microfluidic system. Lab Chip. https://doi.org/10.1039/b307960k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.