The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Miniature biofuel cells
Abstract
The history of electrochemical power sources shows that batteries or fuel cells were introduced only when the development of new electrical or electronic system demanded these. At this time, the already established feasibility of miniaturization of implantable sensor-transmitter systems to volumes smaller than 1 mm3, and the demand for spatially and temporally resolved information on local temperature, flow, pressure and chemical concentrations, are likely to create a demand for a miniature, low cost glucose-O2 biofuel cell that would power the autonomous sensor–transmitters for a few weeks. Prototypes of these cells are in hand. Their most unique feature which is their structural simplicity, is made possible by the selectivity of their “wired” enzyme catalysts: the cells consist merely of two 7 μm diameter carbon fibers, each coated with a different “wired” enzyme bioelectrocatalyst. On one, catalyzing the two-electron electrooxidation of glucose at a reducing potential, glucose oxidase is co-immobilized in and electrically connected (“wired”) by an electron conducting hydrogel of a reducing redox potential. On the other, catalyzing the four electron electroreduction of O2 to water, bilirubin oxidase is co-immobilized in and electrically “wired” by an electron conducting hydrogel of an oxidizing potential. The cells are the smallest ever built. When the volume of the fibers is 0.0026 mm3, the current of the cell operating at 0.52 V in a physiological buffer solution at 37 °C is 8.3 μA. The 4.3 μW power output of the cell is expected to suffice for the operation of implanted sensors and for the intermittent transmission of the data collected to an external receiver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citation
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationExtended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
Stretchable biofuel cell with enzyme-modified conductive textiles
Ogawa, Y., Takai, Y., Kato, Y., Kai, H., Miyake, T., & Nishizawa, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.063 · Cited by 76
Metadata
- Authors
- Heller, A.
- Venue
- Physical Chemistry Chemical Physics
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 6
- Issue
- 2
- Pages
- 209
- ISSN
- 1463-9076 (ISSN-L)
- 1463-9084
- OpenAlex
- W2037659490
- Cited by
- 660
- References
- 1
- FWCI
- 26.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Miniature biofuel cells. https://app.cochat.ai/papers/10.1039/b313149a
- The paper
- Heller, A. (2004). Miniature biofuel cells. Physical Chemistry Chemical Physics. https://doi.org/10.1039/b313149a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.