The DOI matches its Crossref record.
Deep desulfurization of oil refinery streams by extraction with ionic liquids
Abstract
Extraction of S- and N-compounds from gasoline and diesel oil by ionic liquids (ILs) indicates that such a process could be an alternative to common hydrodesulfurization (HDS) for deep desulfurization down to values of 10 ppm S or even lower. The results show the selective extraction properties of ILs, especially with regard to those S-compounds which are hard to remove by HDS, e.g. dibenzothiophene derivatives present in middle distillates like diesel oil. The application of mild process conditions (ambient pressure and temperature) and the fact that no hydrogen is needed, are additional advantages compared to HDS. Very promising ILs are [BMIM][OcSO4] and [EMIM][EtSO4], as they are halogen-free and available from relatively cheap starting materials. Extraction with ILs is not limited to diesel oil, but probably even more attractive for FCC-gasoline. Although HDS of S-species present in this gasoline constituent – mainly thiophenes – is relatively straightforward, a major drawback is the loss in octane number by olefin saturation, which favours extraction with ILs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids and catalysis: Recent progress from knowledge to applications
Olivier-Bourbigou, H., Magna, L., & Morvan, D. (2010) · Applied Catalysis A: General · doi:10.1016/j.apcata.2009.10.008 · Cited by 1,639
Use of ionic liquids as ‘green’ solvents for extractions
Zhao, H., Xia, S., & Ma, P. (2005) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1333 · Cited by 873
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Ionic Liquids in Chemical Engineering
Werner, S., Haumann, M., & Wasserscheid, P. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100915 · Cited by 373
Self-citationRecovery and purification of ionic liquids from solutions: a review
Zhou, J., Sui, H., Jia, Z., Yang, Z., He, L., & Li, X. (2018) · RSC Advances · doi:10.1039/c8ra06384b · Cited by 292
Metadata
- Authors
- Eßer, J., Wasserscheid, P., & Jess, A.
- Venue
- Green Chem.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 6
- Issue
- 7
- Pages
- 316-322
- ISSN
- 1463-9262 (ISSN-L)
- 1463-9270
- OpenAlex
- W2106149783
- Cited by
- 573
- References
- 0
- FWCI
- 48.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep desulfurization of oil refinery streams by extraction with ionic liquids. https://app.cochat.ai/papers/10.1039/b407028c
- The paper
- Eßer, J., Wasserscheid, P., & Jess, A. (2004). Deep desulfurization of oil refinery streams by extraction with ionic liquids. Green Chem. https://doi.org/10.1039/b407028c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.