The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Ionic Liquids in Chemical Engineering
Open accessAbstract
The development of engineering applications with ionic liquids stretches back to the mid-1990s when the first examples of continuous catalytic processes using ionic liquids and the first studies of ionic liquid–based extractions were published. Ever since, the use of ionic liquids has seen tremendous progress in many fields of chemistry and engineering, and the first commercial applications have been reported. The main driver for ionic liquid engineering applications is to make practical use of their unique property profiles, which are the result of a complex interplay of coulombic, hydrogen bonding and van der Waals interactions. Remarkably, many ionic liquid properties can be tuned in a wide range by structural modifications at their cation and anion. This review highlights specific examples of ionic liquid applications in catalysis and in separation technologies. Additionally, the application of ionic liquids as working fluids in process machines is introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2002) · Wiley eBooks · doi:10.1002/3527600701 · Cited by 3,960
Nanoparticles as Recyclable Catalysts: The Frontier between Homogeneous and Heterogeneous Catalysis
Astruc, D., Lu, F., & Aranzaes, J. R. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500766 · Cited by 3,131
(2007) · Wiley eBooks · doi:10.1002/9783527621194 · Cited by 2,768
Pârvulescu, V. I., & Hardacre, C. (2007) · Chemical Reviews · doi:10.1021/cr050948h · Cited by 2,377
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998) · Chem. Commun. · doi:10.1039/a803999b · Cited by 2,167
(1999) · Choice Reviews Online · doi:10.5860/choice.36-5112 · Cited by 1,774
Room-temperature ionic liquids: a novel versatile lubricant.
Ye, C., Liu, W., Chen, Y., & Yu, L. (2001) · Chemical Communications · doi:10.1039/b106935g · Cited by 1,064
Anion Effects on Gas Solubility in Ionic Liquids
Anthony, J. L., Anderson, J. L., Maginn, E. J., & Brennecke, J. F. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp046404l · Cited by 1,058
H. Davis, J. (2004) · Chemistry Letters · doi:10.1246/cl.2004.1072 · Cited by 1,053
Cited by
Multiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Rufford, T. E., Smart, S., Watson, G. C. Y., Graham, B. F., Boxall, J., Diniz da Costa, J. C., & May, E. F. (2012) · Journal of Petroleum Science and Engineering · doi:10.1016/j.petrol.2012.06.016 · Cited by 676
Ionic liquids and deep eutectic mixtures: Sustainable solvents for extraction processes
Pena‐Pereira, F., & Namieśnik, J. (2014) · ChemSusChem · doi:10.1002/cssc.201301192 · Cited by 432
Metadata
- Authors
- Werner, S., Haumann, M., & Wasserscheid, P.
- Venue
- Annual Review of Chemical and Biomolecular Engineering
- Publisher
- Annual Reviews
- Published
- 2010-06-15
- Volume
- 1
- Issue
- 1
- Pages
- 203-230
- ISSN
- 1947-5438 (ISSN-L)
- 1947-5446
- OpenAlex
- W2146491209
- Cited by
- 373
- References
- 92
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic Liquids in Chemical Engineering. https://app.cochat.ai/papers/10.1146/annurev-chembioeng-073009-100915
- The paper
- Werner, S., Haumann, M., & Wasserscheid, P. (2010). Ionic Liquids in Chemical Engineering. Annual Review of Chemical and Biomolecular Engineering. https://doi.org/10.1146/annurev-chembioeng-073009-100915
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.