The DOI matches its Crossref record.
Size-controlled preparation of magnetite nanoparticles in the presence of graft copolymers
Abstract
Stable aqueous iron oxide nanoparticle dispersions were prepared by coprecipitation of ferrous (Fe2+) and ferric (Fe3+) aqueous solution by a base in the presence of graft copolymers, poly(glycerol monoacrylate)-g-poly(PEG methyl ether acrylate) (PGA-g-PEG). PGA-g-PEG was prepared by acidic hydrolysis of poly(solktal acrylate)-g-poly(PEG methyl ether acrylate), which was synthesized by copolymerization of solktal acrylate and PEG methyl ether acrylate by atom transfer radical polymerization (ATRP). The size of the magnetite nanoparticles can be controlled from 4 nm to 18 nm by varying the graft density of the graft copolymers. Structural characterization using X-ray diffraction showed the presence of only the magnetite phase in the nanoparticles. Thermogravimetric analysis confirmed the presence of the graft copolymers on the magnetite surface. The magnetic characterization of the nanoparticles showed that they were superparamagnetic at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kango, S., Kalia, S., Celli, A., Njuguna, J., Habibi, Y., & Kumar, R. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.02.003 · Cited by 2,157
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Synthesis and characterization of magnetite nanoparticles via the chemical co-precipitation method
Petcharoen, K., & Sirivat, A. (2012) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2012.01.003 · Cited by 910
Preparation and application of magnetic Fe3O4 nanoparticles for wastewater purification
Shen, Y. F., Tang, J., Nie, Z. H., Wang, Y. D., Ren, Y., & Zuo, L. (2009) · Separation and Purification Technology · doi:10.1016/j.seppur.2009.05.020 · Cited by 570
Figuerola, A., Di Corato, R., Manna, L., & Pellegrino, T. (2010) · Pharmacological Research · doi:10.1016/j.phrs.2009.12.012 · Cited by 480
Synthesis of Fe3O4 nanoparticles with various sizes and magnetic properties by controlled hydrolysis
Iida, H., Takayanagi, K., Nakanishi, T., & Osaka, T. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.05.047 · Cited by 462
Sharma, R. K., Dutta, S., Sharma, S., Zboril, R., Varma, R. S., & Gawande, M. B. (2016) · Green Chemistry · doi:10.1039/c6gc00864j · Cited by 395
Magnetic nanoparticles: a novel platform for cancer theranostics
Singh, A., & Sahoo, S. K. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.10.005 · Cited by 289
Giraldo, L., Erto, A., & Moreno-Piraján, J. C. (2013) · Adsorption · doi:10.1007/s10450-012-9468-1 · Cited by 284
Sodipo, B. K., & Aziz, A. A. (2016) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2016.05.019 · Cited by 169
Metadata
- Authors
- Wan, S., Huang, J., Yan, H., & Liu, K.
- Venue
- J. Mater. Chem.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 16
- Issue
- 3
- Pages
- 298-303
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W1971079720
- Cited by
- 169
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.