Contamination of Canadian and European bottled waters with antimony from PET containers
Abstract
Using clean lab methods and protocols developed for measuring Sb in polar snow and ice, we report the abundance of Sb in fifteen brands of bottled water from Canada and forty-eight from Europe. Comparison with the natural abundance of Sb in pristine groundwaters, water bottled commercially in polypropylene, analyses of source waters prior to bottling, and addition of uncontaminated groundwater to PET bottles, provides unambiguous evidence of Sb leaching from the containers. In contrast to the pristine groundwater in Ontario, Canada containing 2.2 +/- 1.2 ng l(-1) Sb, 12 brands of bottled natural waters from Canada contained 156 +/- 86 ng l(-1) and 3 brands of deionized water contained 162 +/- 30 ng l(-1); all of these were bottled in PET containers. Natural water from Ontario bottled in polypropylene contained only 8.2 +/- 0.9 ng l(-1). Comparison of three German brands of water available in both glass bottles and PET containers showed that waters bottled in PET contained up to 30 times more Sb. To confirm that the elevated Sb concentrations are due to leaching from the PET containers, water was collected in acid-cleaned LDPE bottles from a commercial source in Germany, prior to bottling; this water was found to contain 3.8 +/- 0.9 ng l(-1) Sb (n = 5), compared with the same brand of water purchased locally in PET bottles containing 359 +/- 54 ng l(-1) (n = 6). This same brand of water in PET bottles, after an additional three months of storage at room temperature, yielded 626 +/- 15 ng l(-1) Sb (n = 3). Other German brands of water in PET bottles contained 253-546 ng l(-1) Sb (n = 5). The median concentration of Sb in thirty-five brands of water bottled in PET from eleven other European countries was 343 ng l(-1) (n = 35). As an independent check of the hypothesis that Sb is leaching from PET, the pristine groundwater from Canada (containing 2.2 +/- 1.2 ng l(-1) Sb) was collected from the source using PET bottles from Germany: this water contained 50 +/- 17 ng l(-1) Sb (n = 2) after only 37 days, even though it was stored in the refrigerator, and 566 ng l(-1) after six months storage at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Halden, R. U. (2010) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.012809.103714 · Cited by 862
Antimony in the environment: knowns and unknowns
Filella, M., Williams, P. A., & Belzile, N. (2009) · Environmental Chemistry · doi:10.1071/en09007 · Cited by 349
Antimony leaching from polyethylene terephthalate (PET) plastic used for bottled drinking water
Westerhoff, P., Prapaipong, P., Shock, E., & Hillaireau, A. (2008) · Water Research · doi:10.1016/j.watres.2007.07.048 · Cited by 344
Wagner, M., & Oehlmann, J. (2009) · Environmental Science and Pollution Research · doi:10.1007/s11356-009-0107-7 · Cited by 343
Impacts of food contact chemicals on human health: a consensus statement
Muncke, J., Andersson, A.-M., Backhaus, T., Boucher, J. M., Carney Almroth, B., Castillo Castillo, A., Chevrier, J., Demeneix, B. A., Emmanuel, J. A., Fini, J.-B., et al. (2020) · Environmental Health · doi:10.1186/s12940-020-0572-5 · Cited by 264
Metadata
- Authors
- Shotyk, W., Krachler, M., & Chen, B.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 8
- Issue
- 2
- Pages
- 288
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W2103992982
- Cited by
- 225
- References
- 0
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contamination of Canadian and European bottled waters with antimony from PET containers. https://app.cochat.ai/papers/10.1039/b517844b
- The paper
- Shotyk, W., Krachler, M., & Chen, B. (2006). Contamination of Canadian and European bottled waters with antimony from PET containers. Journal of Environmental Monitoring. https://doi.org/10.1039/b517844b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.