The DOI matches its Crossref record.
Use of multiple unconfined compression for control of collagen gel scaffold density and mechanical properties
Abstract
Collagen gel is a poroelastic/biphasic system consisting of a fibrillar loose lattice structure filled with >99% fluid. Its mechanical behaviour is governed by the inherent viscoelasticity of the fibrils, and their interaction with the fluid. This study investigated the underlying mechanisms of plastic compression (PC), a recently introduced technique for the production of dense collagen matrices for tissue engineering. Unconfined compressive loading results in the rapid expulsion of the fluid phase to produce scaffolds with improved mechanical properties potentially suitable for direct implantation and suturing. The controllability of the PC, as a single or multi-stage process was investigated in terms of fluid loss, remaining protein concentration, and morphological characteristics. Time dependent analysis, and quasi-static mechanical (compressive and tensile) properties of hyper-hydrated and PC collagen, produced by single (SC) and double (DC) compression, were also investigated on the non-covalently cross-linked gels. Under unconfined compressive creep, the behaviour of hyper hydrated gel was dictated by the fluid movement relative to the solid ( poroelasticity) with negligible recovery upon load removal. Similar behaviour was achieved in multiple compressed gels; however, these progressively dense matrices displayed an instantaneous recovery that was in line with the increase in fibrillar collagen concentration. Under tension, where the mechanical response of the gels is dominated by the fibrils, there was significant increase in both break strength and modulus with increasing fibril concentration due to multiple compression as DC provided greater opportunity for physical interaction between the nano-sized fibrils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Epicardial FSTL1 reconstitution regenerates the adult mammalian heart
Wei, K., Serpooshan, V., Hurtado, C., Diez-Cuñado, M., Zhao, M., Maruyama, S., Zhu, W., Fajardo, G., Noseda, M., Nakamura, K., et al. (2015) · Nature · doi:10.1038/nature15372 · Cited by 489
Review: Development of clinically relevant scaffolds for vascularised bone tissue engineering
Liu, Y., Lim, J., & Teoh, S.-H. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.10.003 · Cited by 427
3D tumour models: novel in vitro approaches to cancer studies
Nyga, A., Cheema, U., & Loizidou, M. (2011) · Journal of Cell Communication and Signaling · doi:10.1007/s12079-011-0132-4 · Cited by 407
Self-citationEngineering the Regenerative Microenvironment with Biomaterials
Rice, J. J., Martino, M. M., De Laporte, L., Tortelli, F., Briquez, P. S., & Hubbell, J. A. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201200197 · Cited by 389
Metadata
- Authors
- Abou Neel, E. A., Cheema, U., Knowles, J. C., Brown, R. A., & Nazhat, S. N.
- Venue
- Soft Matter
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 2
- Issue
- 11
- Pages
- 986
- ISSN
- 1744-683X (ISSN-L)
- 1744-6848
- OpenAlex
- W2105525202
- Cited by
- 199
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of multiple unconfined compression for control of collagen gel scaffold density and mechanical properties. https://app.cochat.ai/papers/10.1039/b609784g
- The paper
- Abou Neel, E. A., Cheema, U., Knowles, J. C., Brown, R. A., & Nazhat, S. N. (2006). Use of multiple unconfined compression for control of collagen gel scaffold density and mechanical properties. Soft Matter. https://doi.org/10.1039/b609784g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.