The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A micro-spherical heart pump powered by cultured cardiomyocytes
Abstract
Miniaturization of chemical or biochemical systems creates extremely efficient devices exploiting the advantages of microspaces. Although they are often targeted for implanted tissue engineered organs or drug-delivery devices because of their highly integrated systems, microfluidic devices are usually powered by external energy sources and therefore difficult to be used in vivo. A microfluidic device powered without the need for external energy sources or stimuli is needed. Previously, we demonstrated the concept of a cardiomyocyte pump using only chemical energy input to cells as a driver (Yo Tanaka, Keisuke Morishima, Tatsuya Shimizu, Akihiko Kikuchi, Masayuki Yamato, Teruo Okano and Takehiko Kitamori, Lab Chip, 6(3), pp. 362-368). However, the structure of this prototype pump described there included complicated mechanical components and fabricated compartments. Here, we have created a micro-spherical heart-like pump powered by spontaneously contracting cardiomyocyte sheets driven without a need for external energy sources or coupled stimuli. This device was fabricated by wrapping a beating cardiomyocyte sheet exhibiting large contractile forces around a fabricated hollow elastomeric sphere (5 mm diameter, 250 microm polymer thickness) fixed with inlet and outlet ports. Fluid oscillations in a capillary connected to the hollow sphere induced by the synchronously pulsating cardiomyocyte sheet were confirmed, and the device continually worked for at least 5 days in this system. This bio/artificial hybrid fluidic pump device is innovative not only because it is driven by cells using only chemical energy input, but also because the design is an optimum structure (sphere). We anticipate that this device might be applied for various purposes including a bio-actuator for medical implant devices that relies on biochemical energy, not electrical interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Chemically Powered Micro‐ and Nanomotors
Sánchez, S., Soler, L., & Katuri, J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201406096 · Cited by 1,011
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
3D Printing in Pharmaceutical and Medical Applications – Recent Achievements and Challenges
Jamróz, W., Szafraniec, J., Kurek, M., & Jachowicz, R. (2018) · Pharmaceutical Research · doi:10.1007/s11095-018-2454-x · Cited by 707
Nano/Micromotors in (Bio)chemical Science Applications
Guix, M., Mayorga-Martinez, C. C., & Merkoçi, A. (2014) · Chemical Reviews · doi:10.1021/cr400273r · Cited by 535
Cole, M. A., Voelcker, N. H., Thissen, H., & Griesser, H. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.026 · Cited by 454
Metadata
- Authors
- Tanaka, Y., Sato, K., Shimizu, T., Yamato, M., Okano, T., & Kitamori, T.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 2
- Pages
- 207-212
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1975608706
- Cited by
- 182
- References
- 1
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A micro-spherical heart pump powered by cultured cardiomyocytes. https://app.cochat.ai/papers/10.1039/b612082b
- The paper
- Tanaka, Y., Sato, K., Shimizu, T., Yamato, M., Okano, T., & Kitamori, T. (2007). A micro-spherical heart pump powered by cultured cardiomyocytes. Lab Chip. https://doi.org/10.1039/b612082b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.