The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Molecular rotors—fluorescent biosensors for viscosity and flow
Abstract
Viscosity is a measure of the resistance of a fluid against gradients in flow (shear rate). Both flow and viscosity play an important role in all biological systems from the microscopic (e.g., cellular) to the systemic level. Many methods to measure viscosity and flow have drawbacks, such as the tedious and time-consuming measurement process, expensive instrumentation, or the restriction to bulk sample sizes. Fluorescent environment-sensitive dyes are known to show high sensitivity and high spatial and temporal resolution. Molecular rotors are a group of fluorescent molecules that form twisted intramolecular charge transfer (TICT) states upon photoexcitation and therefore exhibit two competing deexcitation pathways: fluorescence emission and non-radiative deexcitation from the TICT state. Since TICT formation is viscosity-dependent, the emission intensity of molecular rotors depends on the solvent's viscosity. Furthermore, shear-stress dependency of the emission intensity was recently described. Although the photophysical processes are widely explored, the practical application of molecular rotors as sensors for viscosity and the fluid flow introduce additional challenges. Intensity-based measurements are influenced by fluid optical properties and dye concentration, and solvent-dye interaction requires calibration of the measurement system to a specific solvent. Ratiometric dyes and measurement systems help solve these challenges. In addition, the combination of molecular rotors with specific recognition groups allows them to target specific sites, for example the cell membrane or cytoplasm. Molecular rotors are therefore emerging as new biosensors for both bulk and local microviscosity, and for flow and fluid shear stress on a microscopic scale and with real-time response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Singer, S. J., & Nicolson, G. L. (1972) · Science · doi:10.1126/science.175.4023.720 · Cited by 9,154
Mobility measurement by analysis of fluorescence photobleaching recovery kinetics
Axelrod, D., Koppel, D. E., Schlessinger, J., Elson, E., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85755-4 · Cited by 2,714
Fluidity parameters of lipid regions determined by fluorescence polarization
Shinitzky, M., & Barenholz, Y. (1978) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(78)90010-2 · Cited by 1,875
Reinterpretation of the anomalous fluorescense of -n,n-dimethylamino-benzonitrile
Rotkiewicz, K., Grellmann, K. H., & Grabowski, Z. R. (1973) · Chemical Physics Letters · doi:10.1016/0009-2614(73)80367-7 · Cited by 792
Physiology of membrane fluidity
Shinitzky, M. (1984) · CRC Press eBooks · Cited by 671
Die Viskositätsabhängigkeit der Fluoreszenzquantenausbeuten einiger Farbstoffsysteme
Förster, T., & Hoffmann, G. (1971) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1971.75.1_2.063 · Cited by 573
Lipid fluidity markedly modulates the binding of serotonin to mouse brain membranes.
Heron, D. S., Shinitzky, M., Hershkowitz, M., & Samuel, D. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.12.7463 · Cited by 440
Direct relationship between blood pressure and blood viscosity in normal and hypertensive subjects
Letcher, R. L., Chien, S., Pickering, T. G., Sealey, J. E., & Laragh, J. H. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90827-5 · Cited by 352
Shear stress inhibits apoptosis of human endothelial cells
Dimmeler, S., Haendeler, J., Rippmann, V., Nehls, M., & Zeiher, A. M. (1996) · FEBS Letters · doi:10.1016/s0014-5793(96)01289-6 · Cited by 337
The viscosity of human blood plasma; its measurement in health and disease
Harkness, J. (1971) · Biorheology · doi:10.3233/bir-1971-83-408 · Cited by 262
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Singlet oxygen: there is indeed something new under the sun
Ogilby, P. R. (2010) · Chemical Society Reviews · doi:10.1039/b926014p · Cited by 1,266
Klymchenko, A. S. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00517 · Cited by 1,220
Sasaki, S., Drummen, G. P. C., & Konishi, G.-I. (2016) · Journal of Materials Chemistry C · doi:10.1039/c5tc03933a · Cited by 1,189
Twisted Intramolecular Charge Transfer and Aggregation-Induced Emission of BODIPY Derivatives
Hu, R., Lager, E., Aguilar-Aguilar, A., Liu, J., Lam, J. W. Y., Sung, H. H. Y., Williams, I. D., Zhong, Y., Wong, K. S., Peña-Cabrera, E., et al. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp902962h · Cited by 1,023
Fluorescent Analogs of Biomolecular Building Blocks: Design, Properties, and Applications
Sinkeldam, R. W., Greco, N. J., & Tor, Y. (2010) · Chemical Reviews · doi:10.1021/cr900301e · Cited by 837
Molecular Rotor Measures Viscosity of Live Cells via Fluorescence Lifetime Imaging
Kuimova, M. K., Yahioglu, G., Levitt, J. A., & Suhling, K. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800570d · Cited by 815
Discerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Imaging intracellular viscosity of a single cell during photoinduced cell death
Kuimova, M. K., Botchway, S. W., Parker, A. W., Balaz, M., Collins, H. A., Anderson, H. L., Suhling, K., & Ogilby, P. R. (2009) · Nature Chemistry · doi:10.1038/nchem.120 · Cited by 639
Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
Klymchenko, A. S., & Kreder, R. (2014) · Chemistry & Biology · doi:10.1016/j.chembiol.2013.11.009 · Cited by 514
Mapping viscosity in cells using molecular rotors
Kuimova, M. K. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41674c · Cited by 484
A Self-Calibrating Bipartite Viscosity Sensor for Mitochondria
Yang, Z., He, Y., Lee, J.-H., Park, N., Suh, M., Chae, W.-S., Cao, J., Peng, X., Jung, H., Kang, C., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403851p · Cited by 468
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Wang, L., Xiao, Y., Tian, W., & Deng, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311688g · Cited by 464
Peng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1104014 · Cited by 431
Environment-sensitive behavior of fluorescent molecular rotors
Haidekker, M. A., & Theodorakis, E. A. (2010) · Journal of Biological Engineering · doi:10.1186/1754-1611-4-11 · Cited by 429
Self-citationStsiapura, V. I., Maskevich, A. A., Kuzmitsky, V. A., Uversky, V. N., Kuznetsova, I. M., & Turoverov, K. K. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp805822c · Cited by 385
Monitoring Biophysical Properties of Lipid Membranes by Environment-Sensitive Fluorescent Probes
Demchenko, A. P., Mély, Y., Duportail, G., & Klymchenko, A. S. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.02.012 · Cited by 381
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Kim, E., Lee, Y., Lee, S., & Park, S. B. (2015) · Accounts of Chemical Research · doi:10.1021/ar500370v · Cited by 282
A molecular rotor for measuring viscosity in plasma membranes of live cells
López-Duarte, I., Vu, T. T., Izquierdo, M. A., Bull, J. A., & Kuimova, M. K. (2014) · Chem. Commun. · doi:10.1039/c3cc47530a · Cited by 274
Fluorescent Molecular Rotors for Viscosity Sensors
Lee, S., Heo, J., Woo, H. C., Lee, J., Seo, Y. H., Lee, C., Kim, S., & Kwon, O. (2018) · Chemistry – A European Journal · doi:10.1002/chem.201801389 · Cited by 271
Liu, D., Wei, J. Y., Tian, W. W., Jiang, W., Sun, Y. M., Zhao, Z., & Tang, B. Z. (2020) · Chemical Science · doi:10.1039/d0sc02194f · Cited by 109
Metadata
- Authors
- Haidekker, M. A., & Theodorakis, E. A.
- Venue
- Org. Biomol. Chem.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 5
- Issue
- 11
- Pages
- 1669-1678
- ISSN
- 1477-0520 (ISSN-L)
- 1477-0539
- OpenAlex
- W2325531676
- Cited by
- 638
- References
- 29
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.