The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A microfabricated array of clamps for immobilizing and imaging C. elegans
Abstract
This paper describes the fabrication of a microfluidic device for rapid immobilization of large numbers of live C. elegans for performing morphological analysis, microsurgery, and fluorescence imaging in a high-throughput manner. The device consists of two principal elements: (i) an array of 128 wedge-shaped microchannels, or clamps, which physically immobilize worms, and (ii) a branching network of distribution channels, which deliver worms to the array. The flow of liquid through the device (driven by a constant pressure difference between the inlet and the outlet) automatically distributes individual worms into each clamp. It was possible to immobilize more than 100 worms in less than 15 min. The immobilization process was not damaging to the worms: following removal from the array of clamps, worms lived typical lifespans and reproduced normally. The ability to monitor large numbers of immobilized worms easily and in parallel will enable researchers to investigate physiology and behavior in large populations of C. elegans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Self-citationFunctional regeneration after laser axotomy
Yanik, M. F., Cinar, H., Cinar, H. N., Chisholm, A. D., Jin, Y., & Ben-Yakar, A. (2004) · Nature · doi:10.1038/432822a · Cited by 598
Active Currents Regulate Sensitivity and Dynamic Range in C. elegans Neurons
Goodman, M. B., Hall, D. H., Avery, L., & Lockery, S. R. (1998) · Neuron · doi:10.1016/s0896-6273(00)81014-4 · Cited by 370
Cited by
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans
Chung, K., Crane, M. M., & Lu, H. (2008) · Nature Methods · doi:10.1038/nmeth.1227 · Cited by 352
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Johari, S., Nock, V., Alkaisi, M. M., & Wang, W. (2013) · Lab on a Chip · doi:10.1039/c3lc41403e · Cited by 86
Metadata
- Authors
- Hulme, S. E., Shevkoplyas, S. S., Apfeld, J., Fontana, W., & Whitesides, G. M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 11
- Pages
- 1515
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2158677401
- Cited by
- 216
- References
- 3
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfabricated array of clamps for immobilizing and imaging C. elegans. https://app.cochat.ai/papers/10.1039/b707861g
- The paper
- Hulme, S. E., Shevkoplyas, S. S., Apfeld, J., Fontana, W., & Whitesides, G. M. (2007). A microfabricated array of clamps for immobilizing and imaging C. elegans. Lab on a Chip. https://doi.org/10.1039/b707861g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.