An inexpensive light-scattering particle monitor: field validation
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a small, light, passive, inexpensive, datalogging particle monitor called the "UCB" (University of California Berkeley particle monitor). Following previously published laboratory assessments, we present here results of tests of its performance in field settings at high particle concentrations. We demonstrate the mass sensitivity of the UCB in relation to gravimetric filter-based PM(2.5) mass estimates as well as commercial light-scattering instruments co-located in field chamber tests and in kitchens of wood-burning households. The coefficient of variation of the unadjusted UCB mass response in relation to gravimetric estimates was 15%. Although requiring adjustment for differences in sensitivity, inter-monitor performance was consistently high (r(2) > 0.99). Moreover, the UCB can consistently estimate PM(2.5) mass concentrations in wood-burning kitchens (Pearson r(2) = 0.89; N = 99), with good agreement between duplicate measures (Pearson r(2) = 0.94; N = 88). In addition, with appropriate cleaning of the sensing chamber, UCB mass sensitivity does not decrease with time when used intensively in open woodfire kitchens, demonstrating the significant potential of this monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
Self-citationLow-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis
Concas, F., Mineraud, J., Lagerspetz, E., Varjonen, S., Liu, X., Puolamäki, K., Nurmi, P., & Tarkoma, S. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3446005 · Cited by 265
Balakrishnan, K., Ghosh, S., Ganguli, B., Sambandam, S., Bruce, N., Barnes, D. F., & Smith, K. R. (2013) · Environmental Health · doi:10.1186/1476-069x-12-77 · Cited by 197
Self-citationHousehold electrification and indoor air pollution
Barron, M., & Torero, M. (2017) · Journal of Environmental Economics and Management · doi:10.1016/j.jeem.2017.07.007 · Cited by 180
Metadata
- Authors
- Chowdhury, Z., Edwards, R. D., Johnson, M., Naumoff Shields, K., Allen, T., Canuz, E., & Smith, K. R.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 9
- Issue
- 10
- Pages
- 1099
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W2094195520
- Cited by
- 72
- References
- 0
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An inexpensive light-scattering particle monitor: field validation. https://app.cochat.ai/papers/10.1039/b709329m
- The paper
- Chowdhury, Z., Edwards, R. D., Johnson, M., Naumoff Shields, K., Allen, T., Canuz, E., & Smith, K. R. (2007). An inexpensive light-scattering particle monitor: field validation. Journal of Environmental Monitoring. https://doi.org/10.1039/b709329m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.