Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 610

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Signal enhancement in laser ablation ICP-MS by addition of nitrogen in the central channel gas

Hu, Zhaochu, Gao, Shan, Liu, Yongsheng, Hu, Shenghong, Chen, Haihong, Yuan, Honglin · 2008 · Journal of Analytical Atomic Spectrometry

Abstract

The effects of adding nitrogen to the central gas flow (Ar + He) of an Ar plasma in laser ablation inductively coupled plasma mass spectrometry are presented. The optimum central gas flow rate was found to be negatively correlated with the N2 gas flow rate. The addition of 5–10 ml min−1nitrogen to the central channel gas in LA-ICP-MS increases the sensitivity for most of the 65 investigated elements by a factor of 2–3. The degree of enhancement depends, to some extent, on the 1st ionization energy. Another important advantage of N2 mixed gas plasma for LA-ICP-MS is that the oxide ratios (ThO+/Th+) are significantly reduced (one order of magnitude). The hydride ratio (ArH+/Ar+) is also reduced up to a factor of 3, whereas the doubly charged ion ratio (Ca2+/Ca+) is increased. The background signals at masses 29, 31, 42, 51, 52 and 55 are significantly increased due to the nitrogen based polyatomic interferences. Compared to the spatial profiles of the ion distributions in the normal mode (without nitrogen), the addition of 5 ml min−1nitrogen leads to significant wider axial profiles and more uniform distribution of ions with different physical and chemical properties. Our results also show that the makeup gas flow (central channel gas) rate has a significant effect on the ion distribution of elements with different physical and chemical properties. A very consistent increase of argon signal by the addition of nitrogen (5 ml min−1) corroborates better energy transfer effect of nitrogen in the plasma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b804760j

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 610

Metadata

Authors
Hu, Z., Gao, S., Liu, Y., Hu, S., Chen, H., & Yuan, H.
Venue
Journal of Analytical Atomic Spectrometry
Published
2008
Volume
23
Issue
8
Pages
1093
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2043063526
Cited by
610
References
7
FWCI
18.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Signal enhancement in laser ablation ICP-MS by addition of nitrogen in the central channel gas. https://app.cochat.ai/papers/10.1039/b804760j
The paper
Hu, Z., Gao, S., Liu, Y., Hu, S., Chen, H., & Yuan, H. (2008). Signal enhancement in laser ablation ICP-MS by addition of nitrogen in the central channel gas. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b804760j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.