The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Repair of enamel by using hydroxyapatite nanoparticles as the building blocks
Abstract
The application of calcium phosphates and their nanoparticles have been received great attention. However, hydroxyapatite (HAP) is not suggested in dental therapy to repair the damaged enamel directly although this compound has a similar chemical composition to enamel. We note that the size-effects of HAP are not taken into account in the previous studies as these artificial particles frequently have sizes of hundreds of nanometres. It has recently been revealed that the basic building blocks of enamel are 20–40 nm HAP nanoparticles. We suggest that the repair effect of HAP can be greatly improved if its dimensions can be reduced to the scale of the natural building blocks. Compared with conventional HAP and nano amorphous calcium phosphate (ACP), our in vitro experimental results demonstrate the advantages of 20 nm HAP in enamel repairs. The results of scanning electron microscopy, confocal laser scanning microscopy, quantitative measurement of the adsorption, dissolution kinetics, and nanoindentation, show the strong affinity, excellent biocompatibility, mechanical improvement, and the enhancement of erosion-free by using 20 nm particles as the repairing agent. However, these excellent in vitro repair effects cannot be observed when conventional HAP and ACP are applied. Clearly, nano HAP with a size of 20 nm shares similar characteristics to the natural building blocks of enamel so that it may be used as an effective repair material and anticaries agent. Our current study highlights the analogues of nano building blocks of biominerals during biomedical applications, which provide a novel pathway for biomimetic repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selwitz, R. H., Ismail, A. I., & Pitts, N. B. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60031-2 · Cited by 2,617
Cited by
Nanosized and nanocrystalline calcium orthophosphates
Dorozhkin, S. V. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.031 · Cited by 552
Advances in synthesis of calcium phosphate crystals with controlled size and shape
Lin, K., Wu, C., & Chang, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.017 · Cited by 414
Nanomaterials in preventive dentistry
Hannig, M., & Hannig, C. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.83 · Cited by 414
Dorozhkin, S. V. (2011) · Biomatter · doi:10.4161/biom.18790 · Cited by 370
Nanoparticles used in dentistry: A review
Priyadarsini, S., Mukherjee, S., & Mishra, M. (2018) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2017.12.004 · Cited by 320
Metadata
- Authors
- Li, L., Pan, H., Tao, J., Xu, X., Mao, C., Gu, X., & Tang, R.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 18
- Issue
- 34
- Pages
- 4079
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2144843314
- Cited by
- 266
- References
- 1
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Repair of enamel by using hydroxyapatite nanoparticles as the building blocks. https://app.cochat.ai/papers/10.1039/b806090h
- The paper
- Li, L., Pan, H., Tao, J., Xu, X., Mao, C., Gu, X., & Tang, R. (2008). Repair of enamel by using hydroxyapatite nanoparticles as the building blocks. Journal of Materials Chemistry. https://doi.org/10.1039/b806090h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.