Characterization of drug metabolites and cytotoxicity assay simultaneously using an integrated microfluidic device
The DOI matches its Crossref record.
Abstract
An integrated microfluidic device was developed for the characterization of drug metabolites and a cytotoxicity assay simultaneously. The multi-layer device was composed of a quartz substrate with embedded separation microchannels and a perforated three-microwell array containing sol-gel bioreactors of human liver microsome (HLM), and two PDMS layers. By aligning the microwell array on the quartz substrate with cell culture chambers on the bottom PDMS layer, drug metabolism studies related to functional units, including metabolite generation, detection and incubation with cultured cells to assess metabolism induced cytotoxicity, were all integrated into the microfluidic device. To validate the feasibility of drug metabolism study on the microfluidic chip, UDP-glucuronosyltransferase (UGT) metabolism of acetaminophen (AP) and its effect on hepG2 cytotoxicity were studied first. Then metabolism based drug-drug interaction between AP and phenytoin (PH), which resulted in increased hepG2 cytotoxicity, was proved on this device. All this demonstrated that the developed microfluidic device could be a potential useful tool for drug metabolism and metabolism based drug-drug interaction research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alternative (non-animal) methods for cosmetics testing: current status and future prospects—2010
Adler, S., Basketter, D., Creton, S., Pelkonen, O., van Benthem, J., Zuang, V., Andersen, K. E., Angers-Loustau, A., Aptula, A., Bal-Price, A., et al. (2011) · Archives of Toxicology · doi:10.1007/s00204-011-0693-2 · Cited by 584
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Metadata
- Authors
- Ma, B., Zhang, G., Qin, J., & Lin, B.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 2
- Pages
- 232-238
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2047525305
- Cited by
- 100
- References
- 0
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of drug metabolites and cytotoxicity assay simultaneously using an integrated microfluidic device. https://app.cochat.ai/papers/10.1039/b809117j
- The paper
- Ma, B., Zhang, G., Qin, J., & Lin, B. (2009). Characterization of drug metabolites and cytotoxicity assay simultaneously using an integrated microfluidic device. Lab Chip. https://doi.org/10.1039/b809117j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.