Development of a microfluidic device for the maintenance and interrogation of viable tissue biopsies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A microfluidic based experimental methodology has been developed that offers a biomimetic microenvironment in which pseudo in vivo tissue studies can be carried out under in vitro conditions. Using this innovative technique, which utilizes the inherent advantages of microfluidic technology, liver tissue has been kept in a viable and functional state for over 70 h during which time on-chip cell lysis has been repeatedly performed. Tissue samples were also disaggregated in situ on-chip into individual primary cells, using a collagenase digestion procedure, enabling further cell analysis to be carried out off-line. It is anticipated that this methodology will have a wide impact on biological and clinical research in fields such as cancer prognosis and treatment, drug development and toxicity, as well as enabling better fundamental research into tissue/cell processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Cited by
Polymeric gels and hydrogels for biomedical and pharmaceutical applications
Jagur‐Grodzinski, J. (2010) · Polymers for Advanced Technologies · doi:10.1002/pat.1504 · Cited by 383
Micro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Tumor-on-a-chip for integrating a 3D tumor microenvironment: chemical and mechanical factors
Wan, L., Neumann, C. A., & LeDuc, P. R. (2020) · Lab on a Chip · doi:10.1039/c9lc00550a · Cited by 120
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Multiplexed drug testing of tumor slices using a microfluidic platform
Horowitz, L. F., Rodriguez, A. D., Dereli-Korkut, Z., Lin, R., Castro, K., Mikheev, A. M., Monnat, R. J., Folch, A., & Rostomily, R. C. (2020) · npj Precision Oncology · doi:10.1038/s41698-020-0117-y · Cited by 88
Metadata
- Authors
- Hattersley, S. M., Dyer, C. E., Greenman, J., & Haswell, S. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 11
- Pages
- 1842
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2124611535
- Cited by
- 62
- References
- 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.