CoChat

The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.

Microfluidic devices for in vitro studies on liver drug metabolism and toxicity

van Midwoud, Paul M., Verpoorte, Elisabeth, Groothuis, Geny M. M. · 2011 · Integrative Biology

Abstract

Microfluidic technologies enable the fabrication of advanced in vitro systems incorporating liver tissue or cells to perform metabolism and toxicity studies for drugs and other xenobiotics. The use of microfluidics provides the possibility to utilize a flow of medium, thereby creating a well-controlled microenvironment. The general goals of most in vitro systems in drug research are to optimally mimic the in vivo situation, and to minimize the number of animals required for preclinical studies. Moreover, they may contribute to a reduced attrition rate of drugs at a late stage of the drug development process; this is especially true if human tissue or cells are used. A number of factors are important in achieving good in vivo predictability in microfluidic systems, of which the biological system itself (cells or tissue) and the incubation conditions are the most important. The last couple of years have seen various microfluidic-based in vitro systems being developed to incorporate many different cells and/or tissues. In this review, microfluidics-based in vitro systems realized to study liver metabolism and toxicity are summarized and discussed with respect to their applications, advantages, and limitations. The biological basis of these systems is evaluated, and incubation conditions considered. Precise control of the cell or tissue microenvironment is a key advantage of using microfluidic technologies, and the benefits of exposing the cells to medium flow are demonstrated. Special attention is also paid to the incorporation of multiple cell types or tissues into a microfluidic device for the investigation of interorgan interactions, which are difficult if not impossible to study in conventional systems.

Overview

Integrity signals

Registry

Crossref · 10.1039/c0ib00119h

Cites

123 of 123 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 123 references

Research works printed but not linked: 3

  1. Nyberg, 1994, Ann. Surg., 220, 59
  2. LeCluyse, 2005, Methods Mol. Biol., 290, 207
  3. Neufeld, 1997, Methods Mol. Biol., 75, 145

Cited by

See all 117

Metadata

Authors
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M.
Affiliations
University of Groningen (NL)
Corresponding author
Groothuis, Geny M. M.
Venue
Integrative Biology
Published
2011
Volume
3
Issue
5
Pages
509
ISSN
  • 1757-9694 (ISSN-L)
  • 1757-9708
OpenAlex
W2084745931
Cited by
115
References
123
Citations by year
2026: 1 · 2025: 1 · 2024: 6 · 2023: 4 · 2022: 7 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 14 · 2017: 5 · 2016: 17 · 2015: 9 · 2014: 10 · 2013: 17 · 2012: 6
FWCI
0.89
Type
journal article
Language
en
Open access
closed
Locations
  • Integrative Biology (publishedVersion)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
Keywords
microfluidics, liver drug metabolism, drug toxicity, in vitro liver models, human liver cells, xenobiotic metabolism, microenvironment control, animal use reduction, drug attrition
MeSH terms
Animals, Biological Assay, Equipment Design, Humans, Liver, Pharmacokinetics, Flow Injection Analysis, Toxicity Tests, Cell Culture Techniques, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfluidic devices for in vitro studies on liver drug metabolism and toxicity. https://app.cochat.ai/papers/10.1039/c0ib00119h
The paper
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011). Microfluidic devices for in vitro studies on liver drug metabolism and toxicity. Integrative Biology. https://doi.org/10.1039/c0ib00119h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.