Controlled cocultures of HeLa cells and human umbilical vein endothelial cells on detachable substrates
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We investigated the interactions between HeLa cells and human umbilical vein endothelial cells (HUVECs) by monitoring their movements in a controllable coculture system. Two complementary, detachable, cell-substrates, one of polystyrene (PS) and the other of poly(dimethylsiloxane) (PDMS), were fabricated by replica molding. Coculturing was started by mechanically assembling two complementary substrates. One substrate was covered with a confluent layer of HeLa cells and its complement covered with confluent HUVECs. Using this coculture system as a tumor/endothelium model, we found that the HeLa cells migrated towards the HUVECs, while, simultaneously, the HUVECs retreated and that both types of cells migrated approximately twice as rapidly (two hundred microns per twenty-four hours) as they did alone. Additionally, when direct contact between the two cell types was prevented, the HUVECs initially migrated towards the HeLa cells and then retreated. The characteristics of the cell movements, i.e. direction and speed, probably are consequences of cell-cell signaling, with such signals possibly important during tumor cell intra- and extravasation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Cited by
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
“[40,92] developed endothelium models to study the paracrine communication between endothelial and other cell types.”
BackgroundSelf-citationA microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Hsu, T.-H., Kao, Y.-L., Lin, W.-L., Xiao, J.-L., Kuo, P.-L., Wu, C.-W., Liao, W.-Y., & Lee, C.-H. (2012) · Integr. Biol. · doi:10.1039/c2ib00112h · Cited by 47
Hao, Y., Zhang, L., He, J., Guo, Z., Ying, L., Xu, Z., Zhang, J., Lu, J., & Wang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061754 · Cited by 20
“A number of microfluidic devices have been implemented to study cell-cell interaction [12,13,14,15].”
Background
Metadata
- Authors
- Kaji, H., Yokoi, T., Kawashima, T., & Nishizawa, M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 3
- Pages
- 427-432
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1978370471
- Cited by
- 50
- References
- 1
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.