The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
A microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Open accessAbstract
The living cells are arranged in a complex natural environment wherein they interact with extracellular matrix and other neighboring cells. Cell-cell interactions, especially those between distinct phenotypes, have attracted particular interest due to the significant physiological relevance they can reveal for both fundamental and applied biomedical research. To study cell-cell interactions, it is necessary to develop co-culture systems, where different cell types can be cultured within the same confined space. Although the current advancement in lab-on-a-chip technology has allowed the creation of in vitro models to mimic the complexity of in vivo environment, it is still rather challenging to create such co-culture systems for easy control of different colonies of cells. In this paper, we have demonstrated a straightforward method for the development of an on-chip co-culture system. It involves a series of steps to selectively change the surface property for discriminative cell seeding and to induce cellular interaction in a co-culture region. Bone marrow stromal cells (HS5) and a liver tumor cell line (HuH7) have been used to demonstrate this co-culture model. The cell migration and cellular interaction have been analyzed using microscopy and biochemical assays. This co-culture system could be used as a disease model to obtain biological insight of pathological progression, as well as a tool to evaluate the efficacy of different drugs for pharmaceutical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Instead of simultaneously culturing various cell types in the same chamber, a separate coculture system grows each cell type in a separate chamber and all the cell-cell interaction is achieved by substance diffusion through the culture media between individual culture chambers [131, 139-148] (Figure 4b).”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [142]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidative stress, inflammation, and cancer: How are they linked?
Reuter, S., Gupta, S. C., Chaturvedi, M. M., & Aggarwal, B. B. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2010.09.006 · Cited by 5,441
A Perspective on Cancer Cell Metastasis
Chaffer, C. L., & Weinberg, R. A. (2011) · Science · doi:10.1126/science.1203543 · Cited by 4,807
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
In vitro cell migration and invasion assays
Kramer, N., Walzl, A., Unger, C., Rosner, M., Krupitza, G., Hengstschläger, M., & Dolznig, H. (2013) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2012.08.001 · Cited by 1,170
Protein Nanoarrays Generated By Dip-Pen Nanolithography
Lee, K.-B., Park, S.-J., Mirkin, C. A., Smith, J. C., & Mrksich, M. (2002) · Science · doi:10.1126/science.1067172 · Cited by 1,146
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Inkjet printing for high-throughput cell patterning
Roth, E. A., Xu, T., Das, M., Gregory, C., Hickman, J. J., & Boland, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.052 · Cited by 714
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Chuah, Y. J., Koh, Y. T., Lim, K., Menon, N. V., Wu, Y., & Kang, Y. (2015) · Scientific Reports · doi:10.1038/srep18162 · Cited by 262
Self-citationMicrofluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Trujillo-de Santiago, G., Flores-Garza, B. G., Tavares-Negrete, J. A., Lara-Mayorga, I. M., González-Gamboa, I., Zhang, Y. S., Rojas-Martínez, A., Ortiz-López, R., & Álvarez, M. M. (2019) · Materials · doi:10.3390/ma12182945 · Cited by 184
“[30,56,62,65-68,70-72,85,189-192] [22,23,29,32,43,50,5559,63,64,165,177,194] [21,27,28,47,64]”
Metadata
- Authors
- Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y.
- Affiliations
- Nanyang Technological University (SG)
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2014-11-01
- Volume
- 8
- Issue
- 6
- Pages
- 064118-064118
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC4257957
- OpenAlex
- W2096182522
- Semantic Scholar
- 842571fc3bee0d8a9a2be231eedfca74b36e04ee
- Cited by
- 53
- References
- 54
- Citations by year
- 2026: 2 · 2024: 6 · 2023: 4 · 2022: 7 · 2021: 6 · 2020: 4 · 2019: 8 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 5 · 2014: 1
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomicrofluidics (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Ministry of Education of Singapore (ARC 22/13)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- microfluidic co-culture, tumor-stroma interactions, cell-cell interactions, lab-on-a-chip, mesenchymal stem cells, liver tumor cells, cell migration, extracellular matrix, in vitro disease model, drug efficacy evaluation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidic co-culture system to monitor tumor-stromal interactions on a chip. https://app.cochat.ai/papers/10.1063/1.4903762
- The paper
- Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014). A microfluidic co-culture system to monitor tumor-stromal interactions on a chip. Biomicrofluidics. https://doi.org/10.1063/1.4903762
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.