The DOI matches its Crossref record.
Gold nanodot-based luminescent sensor for the detection of hydrogen peroxide and glucose
Abstract
We unveil a new luminescent assay using 11-mercaptoundecanoic acid-bound Au nanodots (11-MUA-Au NDs) for the highly selective and sensitive detection of hydrogen peroxide and glucose, based on luminescence quenching.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultra-small fluorescent metal nanoclusters: Synthesis and biological applications
Shang, L., Dong, S., & Nienhaus, G. U. (2011) · Nano Today · doi:10.1016/j.nantod.2011.06.004 · Cited by 1,502
Gold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Jv, Y., Li, B., & Cao, R. (2010) · Chemical Communications · doi:10.1039/c0cc02698k · Cited by 936
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Metadata
- Authors
- Shiang, Y.-C., Huang, C.-C., & Chang, H.-T.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Issue
- 23
- Pages
- 3437
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2032603202
- Cited by
- 212
- References
- 0
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gold nanodot-based luminescent sensor for the detection of hydrogen peroxide and glucose. https://app.cochat.ai/papers/10.1039/b901916b
- The paper
- Shiang, Y.-C., Huang, C.-C., & Chang, H.-T. (2009). Gold nanodot-based luminescent sensor for the detection of hydrogen peroxide and glucose. Chemical Communications. https://doi.org/10.1039/b901916b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.