The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Resonant Mie scattering in infrared spectroscopy of biological materials – understanding the ‘dispersion artefact’
Abstract
Infrared spectroscopic cytology is potentially a powerful clinical tool. However, in order for it to be successful, practitioners must be able to extract reliably a pure absorption spectrum from a measured spectrum that often contains many confounding factors. The most intractable problem to date is the, so called, dispersion artefact which most prominently manifests itself as a sharp decrease in absorbance on the high wavenumber side of the amide I band in the measured spectrum, exhibiting a derivative-like line shape. In this paper we use synchrotron radiation FTIR micro-spectroscopy to record spectra of mono-dispersed poly(methyl methacrylate) (PMMA) spheres of systematically varying size and demonstrate that the spectral distortions in the data can be understood in terms of resonant Mie scattering. A full understanding of this effect will enable us to develop strategies for deconvolving the scattering contribution and recovering the pure absorption spectrum, thus removing one of the last technological barriers to the development of clinical spectroscopic cytology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Theory of Dispersion of X-Rays
de L. Kronig, R. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000547 · Cited by 1,987
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Infrared spectroscopic imaging for histopathologic recognition
Fernandez, D. C., Bhargava, R., Hewitt, S. M., & Levin, I. W. (2005) · Nature Biotechnology · doi:10.1038/nbt1080 · Cited by 592
Infrared Spectroscopy of Cells and Tissues: Shining Light onto a Novel Subject
Diem, M., Boydston-White, S., & Chiriboga, L. (1999) · Applied Spectroscopy · doi:10.1366/0003702991946712 · Cited by 338
A decade of vibrational micro-spectroscopy of human cells and tissue (1994–2004)
Diem, M., Romeo, M., Boydston-White, S., Miljković, M., & Matthäus, C. (2004) · The Analyst · doi:10.1039/b408952a · Cited by 290
The laser-Raman and infra-red spectra of poly(methyl methacrylate)
Willis, H. A., Zichy, V. J. I., & Hendra, P. J. (1969) · Polymer · doi:10.1016/0032-3861(69)90101-3 · Cited by 287
Highly resolved chemical imaging of living cells by using synchrotron infrared microspectrometry
Jamin, N., Dumas, P., Moncuit, J., Fridman, W.-H., Teillaud, J.-L., Carr, G. L., & Williams, G. P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.9.4837 · Cited by 251
Self-citationMohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057950 · Cited by 236
The use of synchrotron infrared microspectroscopy in biological and biomedical investigations
Dumas, P., & Miller, L. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00043-2 · Cited by 230
Self-citationResolution limits for infrared microspectroscopy explored with synchrotron radiation
Carr, G. L. (2001) · Review of Scientific Instruments · doi:10.1063/1.1347965 · Cited by 220
FT-IR spectroscopic investigations of single cells on the subcellular level
Lasch, P., Boese, M., Pacifico, A., & Diem, M. (2002) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(01)00153-9 · Cited by 189
Towards a practical Fourier transform infrared chemical imaging protocol for cancer histopathology
Bhargava, R. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1511-9 · Cited by 184
Kohler, A., Sulé-Suso, J., Sockalingum, G. D., Tobin, M., Bahrami, F., Yang, Y., Pijanka, J., Dumas, P., Cotte, M., van Pittius, D. G., et al. (2008) · Applied Spectroscopy · doi:10.1366/000370208783759669 · Cited by 179
Self-citationGazi, E., Dwyer, J., Gardner, P., Ghanbari‐Siahkali, A., Wade, A., Miyan, J., Lockyer, N., Vickerman, J., Clarke, N., Shanks, J., et al. (2003) · The Journal of Pathology · doi:10.1002/path.1421 · Cited by 172
Self-citationBoydston-White, S., Gopen, T., Houser, S., Bargonetti, J., & Diem, M. (1999) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1999)5:4<219::aid-bspy2>3.0.co;2-o · Cited by 166
Gazi, E., Gardner, P., Lockyer, N. P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2007) · Journal of Lipid Research · doi:10.1194/jlr.m700131-jlr200 · Cited by 166
Self-citationAdding synchrotron radiation to infrared microspectroscopy: what's new in biomedical applications?
Dumas, P., Sockalingum, G. D., & Sulé‐Suso, J. (2006) · Trends in biotechnology · doi:10.1016/j.tibtech.2006.11.002 · Cited by 158
Self-citationChio-Srichan, S., Réfrégiers, M., Jamme, F., Kaščáková, S., Rouam, V., & Dumas, P. (2008) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2008.02.004 · Cited by 141
Self-citationGazi, E., Dwyer, J., Lockyer, N. P., Miyan, J. A., Gardner, P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2004) · Biopolymers · doi:10.1002/bip.20167 · Cited by 139
Self-citationGerman, M. J., Hammiche, A., Ragavan, N., Tobin, M. J., Cooper, L. J., Matanhelia, S. S., Hindley, A. C., Nicholson, C., Fullwood, N. J., Pollock, H. M., et al. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.077255 · Cited by 138
Spatially resolved IR microspectroscopy of single cells
Lasch, P., Pacifico, A. M., & Diem, M. (2002) · Biopolymers · doi:10.1002/bip.10095 · Cited by 124
Reflection contributions to the dispersion artefact in FTIR spectra of single biological cells
Bassan, P., Byrne, H. J., Lee, J., Bonnier, F., Clarke, C., Dumas, P., Gazi, E., Brown, M. D., Clarke, N. W., & Gardner, P. (2009) · The Analyst · doi:10.1039/b821349f · Cited by 123
Self-citationSynchrotron infrared microscopy at the French Synchrotron Facility SOLEIL
Dumas, P., Polack, F. A., Lagarde, B., Chubar, O., Giorgetta, J.-L., & Lefrançois, S. (2006) · Infrared Physics & Technology · doi:10.1016/j.infrared.2006.01.030 · Cited by 109
Self-citationInfrared micro-spectral imaging: distinction of tissue types in axillary lymph node histology
Bird, B., Miljković, M. D., Romeo, M., Smith, J. D., Stone, N., George, M. W., & Diem, M. (2008) · BMC Clinical Pathology · doi:10.1186/1472-6890-8-8 · Cited by 108
Imaging capabilities of synchrotron infrared microspectroscopy
Dumas, P., Jamin, N., Teillaud, J., Miller, L. M., & Beccard, B. J. (2003) · Faraday Discussions · doi:10.1039/b305065c · Cited by 102
Self-citationRomeo, M., & Diem, M. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.04.003 · Cited by 98
Romeo, M., Mohlenhoff, B., & Diem, M. (2006) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.04.009 · Cited by 91
Gazi, E., Dwyer, J. P., Lockyer, N. P., et al. (2003) · Faraday Discussions · doi:10.1039/b304883g · Cited by 84
Vibrational spectroscopy and medicine: an alliance in the making
Mantsch, H. H., Choo, L.-P., & Shaw, R. A. (2002) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(02)00036-x · Cited by 69
IR microspectroscopy of live cells
Moss, D. A., Keese, M. A., & Pepperkok, R. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.04.004 · Cited by 67
Gazi, E., Dwyer, J., Lockyer, N. P., Miyan, J. A., Gardner, P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.026 · Cited by 55
Self-citationPijanka, J. K., Köhler, A., Yang, Y., Dumas, P., Chio‐Srichan, S., Manfait, M., Sockalingum, G. D., & Sulé‐Suso, J. (2009) · The Analyst · doi:10.1039/b821112d · Cited by 55
Self-citationLee, J., Gazi, E., Dwyer, J., Brown, M. D., Clarke, N. W., Nicholson, J. M., & Gardner, P. (2007) · The Analyst · doi:10.1039/b702064c · Cited by 54
Self-citationFT-IR microspectroscopy as a tool to assess lung cancer cells response to chemotherapy
Sulé‐Suso, J., Skingsley, D. R., Sockalingum, G. D., Köhler, A., Kegelaer, G., Manfait, M., & Haj, A. J. E. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.010 · Cited by 50
Holman, H. N., Regine Goth-goldstein, A., Martin, M. C., Russell, M., & McKinney, W. R. (2000) · Environmental Science & Technology · doi:10.1021/es991430w · Cited by 45
Cytology by infrared micro-spectroscopy: Automatic distinction of cell types in urinary cytology
Bird, B., Romeo, M., Diem, M., Bedrossian, K., Laver, N., & Naber, S. P. (2008) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2008.03.006 · Cited by 36
Cited by
Using Fourier transform IR spectroscopy to analyze biological materials
Baker, M. J., Trevisan, J., Bassan, P., Bhargava, R., Butler, H. J., Dorling, K. M., Fielden, P. R., Fogarty, S. W., Fullwood, N. J., Heys, K. A., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.110 · Cited by 1,958
Self-citationYang, H., Yang, S., Kong, J., Dong, A., & Yu, S. (2015) · Nature Protocols · doi:10.1038/nprot.2015.024 · Cited by 1,286
Tagg, A. S., Sapp, M., Harrison, J. P., & Ojeda, J. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00495 · Cited by 687
Fenton's reagent for the rapid and efficient isolation of microplastics from wastewater
Tagg, A. S., Harrison, J. P., Ju-Nam, Y., Sapp, M., Bradley, E. L., Sinclair, C. J., & Ojeda, J. J. (2017) · Chemical Communications · doi:10.1039/c6cc08798a · Cited by 450
Harrison, J. P., Ojeda, J. J., & Romero-González, M. E. (2012) · Science of The Total Environment · doi:10.1016/j.scitotenv.2011.11.078 · Cited by 393
Metadata
- Authors
- Bassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 134
- Issue
- 8
- Pages
- 1586
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2043681221
- Cited by
- 316
- References
- 36
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.