CoChat

Sorption of micropollutant estrone to a water treatment ion exchange resin

Open access
Neale, Peta A., Mastrup, Maibritt, Borgmann, Thomas, Schäfer, Andrea I. · 2010 · J. Environ. Monit.
Cited by 51

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Micropollutants occur in natural waters from a range of sources. Estrogenic compounds are naturally excreted by humans and hence stem predominantly from wastewater effluents. Due to their small molecular weight and concentration their effective control is a challenge. In this study magnetic ion exchange (MIEX), which was developed to remove natural organic matter (NOM) from surface water, was investigated for such a micropollutant, estrone. The interaction of estrone with the resin occurs as a side effect when NOM is removed. This interaction results in some degree of removal. However, the accumulation of those hazardous materials on the resin, which can be associated with accidental release, as well as the concentration in the regeneration brine of the process, is environmentally more significant. For this reason a thorough investigation of interaction phenomena was undertaken. Estrone and polymeric materials (such as ion exchange resins or membranes) interact through a number of mechanisms including specific and non-specific interactions. Sorption and desorption of estrone were studied as a function of pH, temperature, natural organic matter concentration, sulfate concentration and ionic strength to elucidate possible mechanisms. The results demonstrated that the resin removed around 70% estrone at high pH conditions (>10.4) when estrone was predominantly negatively charged. However, below pH 10.4, when estrone was neutral, approximately 40% of estrone still sorbed due to hydrogen bonding. The optimum temperature for estrone sorption was observed to be in the 15 to 35 degrees C range, while the presence of other anions, including natural organic matter reduced estrone removal due to competition for anion exchange sites. Desorption of estrone was most effective with 2 M NaCl regeneration brine concentration when estrone was negatively charged (98% desorption). However, when estrone was neutral there was no significant difference between 1 M and 2 M NaCl. The results presented in this study indicate that polar non-ionic micropollutants were removed by magnetic ion exchange resin due to sorption to the resin polymer. This has implications for treatment, however, the accumulation of micropollutants on polymeric materials in water treatment as well as the abundance of such micropollutants in the regeneration brine are risks that warrant monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b913338k

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Neale, P. A., Mastrup, M., Borgmann, T., & Schäfer, A. I.
Venue
J. Environ. Monit.
Published
2010
Volume
12
Issue
1
Pages
311-317
ISSN
  • 1464-0325 (ISSN-L)
  • 1464-0333
OpenAlex
W2138904474
Cited by
51
References
1
FWCI
2.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.