A new method for studying gradient-induced neutrophil desensitization based on an open microfluidic chamber
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
During inflammation neutrophils rapidly migrate to the site of tissue damage or infection by following complex gradients of bacterial peptides and host-derived chemokines. The efficiency and speed of neutrophil migration is critically dependent upon the ability of neutrophils to sense new gradients and utilize only those that provide the most direct path to the damaged or infected site. Receptor desensitization plays an important role in migration efficiency and is most commonly studied using bath application of chemotactic factor solutions instead of presenting cells with gradients analogous to those they would experience in vivo. Here we describe a new method for examining gradient-induced neutrophil desensitization using a previously-developed open-chamber microfluidic gradient generator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Self-citation
Cited by
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
3D neural tissue models: From spheroids to bioprinting
Zhuang, P., Sun, A. X., An, J., Chua, C. K., & Chew, S. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.002 · Cited by 270
Simultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Microfluidic single-cell analysis for systems immunology
Junkin, M., & Tay, S. (2014) · Lab on a Chip · doi:10.1039/c3lc51182k · Cited by 96
Metadata
- Authors
- Keenan, T. M., Frevert, C. W., Wu, A., Wong, V., & Folch, A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 1
- Pages
- 116-122
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2056089952
- Cited by
- 67
- References
- 1
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for studying gradient-induced neutrophil desensitization based on an open microfluidic chamber. https://app.cochat.ai/papers/10.1039/b913494h
- The paper
- Keenan, T. M., Frevert, C. W., Wu, A., Wong, V., & Folch, A. (2010). A new method for studying gradient-induced neutrophil desensitization based on an open microfluidic chamber. Lab Chip. https://doi.org/10.1039/b913494h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).