The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Conducting polymer nanowires for chemiresistive and FET-based bio/chemical sensors
Abstract
Conducting polymer nanostructures are emerging materials with tremendous potential for conductometric/field effect transistor (FET) bio/chemical sensors because of their chemical sensitivity and biocompatibility. Herein, we review recent developments in conducting polymer nanowire-based sensors and discuss the impact of several milestones and continuing challenges. Particular attention is given to device fabrication, nanostructure performance enhancement, and functionalization schemes. Several assembly and integration techniques have been developed for single nanowire devices but significant progress is still needed to improve scalability and manufacturability. Future work should focus on high throughput approaches that enable combinatorial screening of conducting polymer nanowires and heterogeneous, high density arrays of conducting polymer nanostructures, deterministically tailored for targeted analytes. The spatial and temporal resolution of conducting polymer nanowires is addressed along with the origin of the sensitivity enhancement. Functionalization routes add another degree of complexity for biosensors and are discussed in the context of nanosensor performance and device fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanofiber Formation in the Chemical Polymerization of Aniline: A Mechanistic Study
Huang, J., & Kaner, R. B. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200460616 · Cited by 756
Cited by
Ijaz, I., Gilani, E., Nazir, A., & Bukhari, A. (2020) · Green Chemistry Letters and Reviews · doi:10.1080/17518253.2020.1802517 · Cited by 992
Organic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Wang, X.-X., Yu, G.-F., Zhang, J., Yu, M., Ramakrishna, S., & Long, Y.-Z. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100704 · Cited by 447
Organic and inorganic nanomaterials: fabrication, properties and applications
Alshammari, B. H., Lashin, M. M. A., Mahmood, M. A., Al-Mubaddel, F. S., Ilyas, N., Rahman, N., Sohail, M., Khan, A., Abdullaev, S. S., & Khan, R. (2023) · RSC Advances · doi:10.1039/d3ra01421e · Cited by 331
Improving the cycling stability of silicon nanowire anodes with conducting polymer coatings
Yao, Y., Liu, N., McDowell, M. T., Pasta, M., & Cui, Y. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21437g · Cited by 308
Metadata
- Authors
- Hangarter, C. M., Bangar, M., Mulchandani, A., & Myung, N. V.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 20
- Issue
- 16
- Pages
- 3131
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2125101623
- Cited by
- 158
- References
- 1
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.