The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection
Abstract
Ultrafast laser writing of waveguides in glasses is a very flexible and simple method for direct on-chip integration of photonic devices. In this work we present a monolithic optofluidic device in fused silica providing label-free and spatially-resolved sensing in a microfluidic channel. A Mach-Zehnder interferometer is inscribed with the sensing arm orthogonally crossing the microfluidic channel and the reference arm passing over it. The interferometer is integrated either with a microchannel fabricated by femtosecond laser technology or into a commercial lab-on-chip for capillary electrophoresis. The device layout, made possible by the unique three-dimensional capabilities of the technique, enables label-free sensing of samples flowing in the microchannel with spatial resolution of about 10 microm and limit of detection down to 10(-4) RIU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrafast Processes for Bulk Modification of Transparent Materials
Itoh, K., Watanabe, W., Nolte, S., & Schaffer, C. B. (2006) · MRS Bulletin · doi:10.1557/mrs2006.159 · Cited by 463
Cited by
Ultrafast lasers—reliable tools for advanced materials processing
Sugioka, K., & Cheng, Y. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.30 · Cited by 1,545
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Femtosecond laser three-dimensional micro- and nanofabrication
Sugioka, K., & Cheng, Y. (2014) · Applied Physics Reviews · doi:10.1063/1.4904320 · Cited by 490
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Femtosecond laser microstructuring: an enabling tool for optofluidic lab‐on‐chips
Osellame, R., Hoekstra, H. J. W. M., Cerullo, G., & Pollnau, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000031 · Cited by 320
Self-citation
Metadata
- Authors
- Crespi, A., Gu, Y., Ngamsom, B., Hoekstra, H. J. W. M., Dongre, C., Pollnau, M., Ramponi, R., van den Vlekkert, H. H., Watts, P., Cerullo, G., & Osellame, R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 9
- Pages
- 1167
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2151490995
- Cited by
- 210
- References
- 1
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection. https://app.cochat.ai/papers/10.1039/b920062b
- The paper
- Crespi, A., Gu, Y., Ngamsom, B., Hoekstra, H. J. W. M., Dongre, C., Pollnau, M., Ramponi, R., van den Vlekkert, H. H., Watts, P., Cerullo, G., & Osellame, R. (2010). Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection. Lab on a Chip. https://doi.org/10.1039/b920062b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.