Sub-attomolar HIV-1 DNA detection using surface-enhanced Raman spectroscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A subattomolar HIV-1 DNA detection assay based on multilayer metal-molecule-metal nanojunctions (NJs) has been developed using surface-enhanced Raman spectroscopy (SERS). There is a two-step mechanism involved. First, label free target DNA facilitated the precipitation of Detection Unit I on the substrate through forming a sandwiched structure based on the capture probe, resulting in the first level amplification of target. Following that, the binding site on Detection probe I was further recognized by Detection Unit II. These two complementary probes acted as bricks to build up the multi-metal-molecule-metal NJs between Au nanoparticles (NPs) that not only created SERS "hot spots" by the conjugated Au NPs, but also obviously decreased the distance between Au NPs and Raman labels. Therefore, the Raman signal of the tag molecules on these detection probes was significantly enhanced due to the distance dependent electromagnetic enhancement (EM) of SERS. With regards to a HIV-1 DNA sequence, the platform could detect a concentration as low as 10(-19) M (approximately 10(-23) mol) with the ability of single base mismatch discrimination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Gold nanoparticles in biomedical applications: recent advances and perspectives
Dykman, L., & Khlebtsov, N. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15166e · Cited by 1,961
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan
Suginta, W., Khunkaewla, P., & Schulte, A. (2013) · Chemical Reviews · doi:10.1021/cr300325r · Cited by 521
Guerrini, L., & Graham, D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35118h · Cited by 441
Metadata
- Authors
- Hu, J., Zheng, P.-C., Jiang, J.-H., Shen, G.-L., Yu, R.-Q., & Liu, G.-K.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 5
- Pages
- 1084
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1995997456
- Cited by
- 88
- References
- 1
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sub-attomolar HIV-1 DNA detection using surface-enhanced Raman spectroscopy. https://app.cochat.ai/papers/10.1039/b920358c
- The paper
- Hu, J., Zheng, P.-C., Jiang, J.-H., Shen, G.-L., Yu, R.-Q., & Liu, G.-K. (2010). Sub-attomolar HIV-1 DNA detection using surface-enhanced Raman spectroscopy. The Analyst. https://doi.org/10.1039/b920358c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.