The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Resonant Mie Scattering (RMieS) correction of infrared spectra from highly scattering biological samples
Open accessAbstract
Infrared spectra of single biological cells often exhibit the 'dispersion artefact' observed as a sharp decrease in intensity on the high wavenumber side of absorption bands, in particular the Amide I band at approximately 1655 cm(-1), causing a downward shift of the true peak position. The presence of this effect makes any biochemical interpretation of the spectra unreliable. Recent theory has shed light on the origins of the 'dispersion artefact' which has been attributed to resonant Mie scattering (RMieS). In this paper a preliminary algorithm for correcting RMieS is presented and evaluated using simulated data. Results show that the 'dispersion artefact' appears to be removed; however, the correction is not perfect. An iterative approach was subsequently implemented whereby the reference spectrum is improved after each iteration, resulting in a more accurate correction. Consequently the corrected spectra become increasingly more representative of the pure absorbance spectra. Using this correction method reliable peak positions can be obtained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
On the Theory of Dispersion of X-Rays
de L. Kronig, R. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000547 · Cited by 1,987
Basement membrane complexes with biological activity
Kleinman, H. K., McGarvey, M. L., Hassell, J. R., Star, V. L., Cannon, F. B., Laurie, G. W., & Martin, G. R. (1986) · Biochemistry · doi:10.1021/bi00350a005 · Cited by 1,502
Hartmann, M. (1984) · Acta Polymerica · doi:10.1002/actp.1984.010350426 · Cited by 1,071
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507
Self-citationBiological applications of infrared spectroscopy
Stuart, B. H., & Ando, D. (1997) · Medical Entomology and Zoology · Cited by 339
Bassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P. (2009) · The Analyst · doi:10.1039/b904808a · Cited by 316
Self-citationHighly resolved chemical imaging of living cells by using synchrotron infrared microspectrometry
Jamin, N., Dumas, P., Moncuit, J., Fridman, W.-H., Teillaud, J.-L., Carr, G. L., & Williams, G. P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.9.4837 · Cited by 251
Self-citationMohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057950 · Cited by 236
The use of synchrotron infrared microspectroscopy in biological and biomedical investigations
Dumas, P., & Miller, L. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00043-2 · Cited by 230
Self-citationWood, B. R., Chiriboga, L., Yee, H., Quinn, M. A., McNaughton, D., & Diem, M. (2004) · Gynecologic Oncology · doi:10.1016/j.ygyno.2003.12.028 · Cited by 226
FT-IR spectroscopic investigations of single cells on the subcellular level
Lasch, P., Boese, M., Pacifico, A., & Diem, M. (2002) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(01)00153-9 · Cited by 189
Kohler, A., Sulé-Suso, J., Sockalingum, G. D., Tobin, M., Bahrami, F., Yang, Y., Pijanka, J., Dumas, P., Cotte, M., van Pittius, D. G., et al. (2008) · Applied Spectroscopy · doi:10.1366/000370208783759669 · Cited by 179
Self-citationBoydston-White, S., Gopen, T., Houser, S., Bargonetti, J., & Diem, M. (1999) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1999)5:4<219::aid-bspy2>3.0.co;2-o · Cited by 166
Gazi, E., Gardner, P., Lockyer, N. P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2007) · Journal of Lipid Research · doi:10.1194/jlr.m700131-jlr200 · Cited by 166
Self-citationGerman, M. J., Hammiche, A., Ragavan, N., Tobin, M. J., Cooper, L. J., Matanhelia, S. S., Hindley, A. C., Nicholson, C., Fullwood, N. J., Montagu-Pollock, H. M., et al. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.077255 · Cited by 145
Gazi, E., Dwyer, J., Lockyer, N. P., Miyan, J. A., Gardner, P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2004) · Biopolymers · doi:10.1002/bip.20167 · Cited by 139
Self-citationSpatially resolved IR microspectroscopy of single cells
Lasch, P., Pacifico, A. M., & Diem, M. (2002) · Biopolymers · doi:10.1002/bip.10095 · Cited by 124
Reflection contributions to the dispersion artefact in FTIR spectra of single biological cells
Bassan, P., Byrne, H. J., Lee, J., Bonnier, F., Clarke, C., Dumas, P., Gazi, E., Brown, M. D., Clarke, N. W., & Gardner, P. (2009) · The Analyst · doi:10.1039/b821349f · Cited by 123
Self-citationSynchrotron infrared microscopy at the French Synchrotron Facility SOLEIL
Dumas, P., Polack, F. A., Lagarde, B., Chubar, O., Giorgetta, J.-L., & Lefrançois, S. (2006) · Infrared Physics & Technology · doi:10.1016/j.infrared.2006.01.030 · Cited by 109
Self-citationImaging capabilities of synchrotron infrared microspectroscopy
Dumas, P., Jamin, N., Teillaud, J., Miller, L. M., & Beccard, B. J. (2003) · Faraday Discussions · doi:10.1039/b305065c · Cited by 102
Self-citationRomeo, M., & Diem, M. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.04.003 · Cited by 98
Romeo, M., Mohlenhoff, B., & Diem, M. (2006) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.04.009 · Cited by 91
Application of Immunohistochemistry to Cytology
Fowler, L. J., & Lachar, W. A. (2008) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2008-132-373-aoitc · Cited by 84
IR microspectroscopy of live cells
Moss, D. A., Keese, M. A., & Pepperkok, R. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.04.004 · Cited by 67
Gazi, E., Dwyer, J., Lockyer, N. P., Miyan, J. A., Gardner, P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.026 · Cited by 55
Self-citationPijanka, J. K., Köhler, A., Yang, Y., Dumas, P., Chio‐Srichan, S., Manfait, M., Sockalingum, G. D., & Sulé‐Suso, J. (2009) · The Analyst · doi:10.1039/b821112d · Cited by 55
Self-citationLee, J., Gazi, E., Dwyer, J., Brown, M. D., Clarke, N. W., Nicholson, J. M., & Gardner, P. (2007) · The Analyst · doi:10.1039/b702064c · Cited by 54
Self-citationFT-IR microspectroscopy as a tool to assess lung cancer cells response to chemotherapy
Sulé‐Suso, J., Skingsley, D. R., Sockalingum, G. D., Köhler, A., Kegelaer, G., Manfait, M., & Haj, A. J. E. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.010 · Cited by 50
Cytology by infrared micro-spectroscopy: Automatic distinction of cell types in urinary cytology
Bird, B., Romeo, M., Diem, M., Bedrossian, K., Laver, N., & Naber, S. P. (2008) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2008.03.006 · Cited by 36
Infrared microspectroscopy of individual human cervical cancer (HeLa) cells
Romeo, M., Matthäus, C., Miljković, M. D., & Diem, M. (2004) · Biopolymers · doi:10.1002/bip.20065 · Cited by 28
Research works printed but not linked: 1
- Kramer, 1927, Atti Congr. Intern. Fisica Como, 2, 545
Cited by
Using Fourier transform IR spectroscopy to analyze biological materials
Baker, M. J., Trevisan, J., Bassan, P., Bhargava, R., Butler, H. J., Dorling, K. M., Fielden, P. R., Fogarty, S. W., Fullwood, N. J., Heys, K. A., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.110 · Cited by 1,958
Self-citationThe Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
ATR-FTIR spectroscopic imaging: recent advances and applications to biological systems
Kazarian, S. G., & Chan, K. L. A. (2013) · The Analyst · doi:10.1039/c3an36865c · Cited by 414
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Tutorial: multivariate classification for vibrational spectroscopy in biological samples
Morais, C. L. M., Lima, K. M. G., Singh, M., & Martin, F. L. (2020) · Nature Protocols · doi:10.1038/s41596-020-0322-8 · Cited by 355
Metadata
- Authors
- Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., Gazi, E., Brown, M., Clarke, N., & Gardner, P.
- Affiliations
- University of Manchester (GB)
- Nofima (NO)
- Dublin Institute of Technology (IE)
- Synchrotron SOLEIL (FR)
- Manchester Academic Health Science Centre (GB)
- Corresponding author
- Gardner, Peter
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 2
- Pages
- 268-277
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2167273463
- Cited by
- 375
- References
- 32
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 12 · 2023: 20 · 2022: 20 · 2021: 21 · 2020: 30 · 2019: 22 · 2018: 19 · 2017: 14 · 2016: 23 · 2015: 34 · 2014: 28 · 2013: 39 · 2012: 27
- FWCI
- 13.50
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion, other-oa)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
- Keywords
- infrared spectra, biological cells, amide I band, peak shift
- MeSH terms
- Algorithms, Computer Simulation, Humans, Male, Prostatic Neoplasms, Reference Standards, Tumor Cells, Cultured, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.