Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record.

Rationally designed fluorescence ‘turn-on’ sensor for Cu2+

Ko, Kyoung Chul, Wu, Jia-Sheng, Kim, Hyun Jung, Kwon, Pil Seung, Kim, Jong Wan, Bartsch, Richard A., Lee, Jin Yong, Kim, Jong Seung·2011·Chemical Communications

Abstract

A rationally designed, coumarin-based fluorescent sensor imino-coumarin (IC) displays high selectivity for Cu(2+) over a variety of competing metal ions in aqueous solution with a significant fluorescence increase. DFT/TDDFT calculations support that the fluorescence 'turn-on' of IC originates from blocking the electron transfer of the nitrogen lone pair upon complexation with Cu(2+). IC was successfully applied to microscopic imaging for detection of Cu(2+) in LLC-MK2 cells (in vitro) and several living organs (in vivo).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c0cc05421f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Ko, K. C., Wu, J.-S., Kim, H. J., Kwon, P. S., Kim, J. W., Bartsch, R. A., Lee, J. Y., & Kim, J. S.
Venue
Chemical Communications
Published
2011
Volume
47
Issue
11
Pages
3165
ISSN
  • 1359-7345 (ISSN-L)
  • 1364-548X
OpenAlex
W2166164809
Cited by
169
References
0
FWCI
7.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rationally designed fluorescence ‘turn-on’ sensor for Cu2+. https://app.cochat.ai/papers/10.1039/c0cc05421f
The paper
Ko, K. C., Wu, J.-S., Kim, H. J., Kwon, P. S., Kim, J. W., Bartsch, R. A., Lee, J. Y., & Kim, J. S. (2011). Rationally designed fluorescence ‘turn-on’ sensor for Cu2+. Chemical Communications. https://doi.org/10.1039/c0cc05421f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.