CoChat

Simultaneous quantitation of parabens, triclosan, and methyl triclosan in indoor house dust using solid phase extraction and gas chromatography-mass spectrometry

Fan, Xinghua, Kubwabo, Cariton, Rasmussen, Pat, Jones-Otazo, Heather · 2010 · Journal of Environmental Monitoring
Cited by 53

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

An integrated analytical method for the simultaneous determination of five parabens (methyl-, ethyl-, propyl-, butyl-, and benzyl-), triclosan, and methyl triclosan in indoor house dust was developed based on gas chromatographic-mass spectrometric technique (GC/MS). Analytes were extracted from dust samples by sonication. After sample cleanup by solid-phase extraction (SPE), the extracts were derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) and then analyzed by gas chromatography coupled with ion trap mass spectrometry operated in multiple reaction monitoring (MRM) mode. For quantitation, isotope-labelled internal standards were used for each corresponding target analyte. Only 0.05 g of dust sample was needed for the analysis. Method detection limits ranged from 6.5 to 10 ng/g, and absolute recoveries from 74% to 92%. The developed method demonstrated good repeatability and reproducibility, with relative standard deviations (RSDs) less than 16% for all the analytes. The analytes were determined in dust samples collected using two vacuum sampling methods from 63 Canadian homes: a sample of fresh or "active" dust (FD) collected using a Pullman-Holt vacuum sampler, and a composite sample taken from the household vacuum cleaner (HD). Methyl paraben, propyl paraben, and triclosan were detected in all HD and FD samples. HD samples yielded median values for methyl paraben, propyl paraben, and triclosan of 1080, 463, and 378 ng/g, respectively, which were comparable to the FD sample medians of 1120, 618 and 571 ng/g. Ethyl paraben was detected at frequencies of 89% in FD and 73% in HD samples, with median values of 52 and 25 ng/g, respectively. Butyl paraben was detected at frequencies of 44% in FD and 75% in HD samples, with median values of <10 and 59 ng/g, respectively. Benzyl paraben and methyl triclosan were not detected in any of the samples collected by either method. Samples collected according to the fresh dust protocol agreed with the household vacuum samples 90% of the time. Widely scattered concentration levels were observed for target analytes from this preliminary set of 63 Canadian samples, which suggests a wide variability in Canadian household exposures to these chemicals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c0em00189a

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Fan, X., Kubwabo, C., Rasmussen, P., & Jones-Otazo, H.
Venue
Journal of Environmental Monitoring
Published
2010
Volume
12
Issue
10
Pages
1891
ISSN
  • 1464-0325 (ISSN-L)
  • 1464-0333
OpenAlex
W2163305599
Cited by
53
References
3
FWCI
2.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.