CoChat

Microfluidics for bacterial chemotaxis

Open access
Ahmed, Tanvir, Shimizu, Thomas S., Stocker, Roman · 2010 · Integrative Biology
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Microfluidics is revolutionizing the way we study the motile behavior of cells, by enabling observations at high spatial and temporal resolution in carefully controlled microenvironments. An important class of such behavior is bacterial chemotaxis, which plays a fundamental role in a broad range of processes, including disease pathogenesis, biofilm formation, bioremediation, and even carbon cycling in the ocean. In biophysical research, bacterial chemotaxis represents a powerful model system to understand how cells and organisms sense and respond to gradients. Using microfluidics to study chemotaxis of free-swimming bacteria presents experimental challenges that are distinct from those arising in chemotaxis studies of surface-adherent cells. Recently, these challenges have been met by the development of advanced microdevices, able to generate flow-free, steady gradients of arbitrary shape. Much attention to date has been focused on tool development. Yet, we are now at an exciting turning point where science begins to balance technology. Indeed, recent microfluidic studies provided new insights on both the mechanisms governing bacterial gradient sensing (e.g. tuning of response sensitivity, discrimination between conflicting gradients) and the large-scale consequences of chemotaxis (e.g. in the oceans). Here we outline the principles underlying recently proposed gradient generators for bacterial chemotaxis, illustrate the advantage of the microfluidic approach through selected examples, and identify a broader set of scientific questions that may now be addressed with this rapidly developing technology. The latest generation of microfluidic gradient generators, in particular, holds appeal for both biophysicists seeking to unravel the fundamental mechanisms of bacterial chemotaxis, and ecologists wishing to model chemotaxis in realistic environments. Time is ripe for a deeper integration between technology and biology in fully bringing to bear microfluidics on studies of this fascinating microbial behavior.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c0ib00049c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

  • Biomimetic tissues on a chip for drug discovery

    Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359

    “Extensive reviews exist on the widespread use of microfluidic devices in biomedical engineering, including drug discovery [2,27,28], stem cell biology [29,30], cancer biology and experimental oncology [31], cell culture and processing [1,2,28,32,33], and probing cellular behaviors such as angiogenesis, migration and c…”
    Background

See all 164

Metadata

Authors
Ahmed, T., Shimizu, T. S., & Stocker, R.
Venue
Integrative Biology
Published
2010
Volume
2
Issue
11-12
Pages
604
ISSN
  • 1757-9694 (ISSN-L)
  • 1757-9708
OpenAlex
W2057029205
Cited by
164
References
2
FWCI
7.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.